10. Repeat all steps for any additional Lenovo servers that require the BMC firmware update to
fix false PSU alerts.
Related links
Troubleshooting hardware issues
on page 45
Upgrading HP ProLiant Gen8 server BIOS for POST errors
Condition
HP ProLiant Gen8 servers may experience unexpected errors during a reboot. This involves the
server displaying POST errors 236 or 239. The server may also reboot unexpectedly and display
POST error 207.
Cause
These POST error conditions are a known issue with some HP ProLiant Gen8 servers. Use the
following procedure to upgrade the server BIOS to the latest version to correct this error.
Important:
The host server must be in maintenance mode to perform a BIOS upgrade. Ensure that the
server is in maintenance mode before beginning this procedure.
Troubleshooting hardware issues
October 2017
Troubleshooting the Avaya Pod Fx
™
50