Pod Orchestration Suite Applications
Ensure your FQDN does not exceed a maximum of 35 characters to avoid a system error message
during logon.
If a blank page appears during login ensure that you are using one of the following supported
browsers:
• Internet Explorer 8.x, 9.x, or 10.x
• Firefox 19.0, 20.0, or 21.0
Note:
This problem is seen only when upgrading POS applications.
Virtualization Performance Fault Manager
If VPFM is installed properly, the network was discovered and the trap viewer shows that traps were
received all events appear on the events browser. If no events appear, ensure that monitoring is
turned on.
MLT configuration problem
The VPFM event browser displays a MLT configuration problem message after a discovery is run on
a VPFM domain. The message is a low priority (level 4) and warns the NOC operator of potential
MLT misconfigurations. To understand the reason for the message click the
Attribute
tab. The
Attribute
tab displays the details.
MLT configuration problem messages can mean that a port is configured as an MLT but the link is
not physically there or VPFM could not find a device on the other end.
If this occurs, ensure that the MLT links for the devices is configured and connected correctly, and
then acknowledge the event.
Managed device warning
As a general warning that an IP address was found in the SONMP, LLDP, or CDP table of a
discovered device, but the IP object did not respond, VPFM displays the following message:
potential managed device <IPO: 172.30.10.23> was not explored during