Trigger: posted
Message: unknown IP availability failure on vnx-avstor-1.
Error Description: unknown IP availability failure on vnx-avstor-1.
Configuring SNMP traps for the SAL Gateway
About this task
Use this task to configure elements of the Avaya Pod Fx to send SNMP traps to the SAL Gateway.
Procedure
1. Configure Avaya Virtual Services Platform 4000 Series switches to send SNMP traps.
a. Start an SSH session with the switch.
b. Log in as the
admin
user.
c. Use the
enable
command to enter Privileged mode.
d. Use the
config t
command to enter Configuration mode.
e. Use the
snmp-server host <gateway_ip_address> v2c readview
command
to add the SAL Gateway as a trap receiver.
f. Use the
save config
command to save the configuration.
g. End the SSH session.
h. Logout.
2. Configure Avaya Virtual Services Platform 7200 Series switches to send SNMP traps.
a. Start an SSH session with the switch.
b. Log in as the
admin
user.
c. Use the
enable
command to enter Privileged mode.
d. Use the
config t
command to enter Configuration mode.
e. Use the
snmp-server host <gateway_ip_address> v2c readview
command
to add the SAL Gateway as a trap receiver.
f. Use the
save config
command to save the configuration.
g. End the SSH session.
h. Logout.
3. Configure Avaya Virtual Services Platform 7000 Series switches to send SNMP traps.
a. Start an SSH session with the switch.
b. Log in as the
admin
user.
c. Use the
config t
command to enter Configuration mode.
d. Use the
snmp-server host <gateway_ip_address> avaya123
command to
add the SAL Gateway as a trap receiver.
Configuring alarm notifications
October 2017
Troubleshooting the Avaya Pod Fx
™
21