Install New Firmware on the G700
Issue 7 January 2005
163
4. Refer to the VOIP FW column and row for slot V0 (same row occupied by the G700
information) to see if the number matches the VoIP firmware identified in your planning
forms.
If not, you must also upgrade the G700 media gateway motherboard VoIP module.
Note:
Note:
The VoIP processor on the motherboard is upgraded using the same firmware
image file as the VoIP media modules; for example, the file mm760v8.fdl is
vintage #8.
5. Check the FW VINTAGE column for vintages of each of the installed media modules:
MM710, MM711, MM712, MM720, and/or MM760 to see if they match the FW vintages in
the planning forms.
If not, you must upgrade them, as well.
Installing New Firmware on the P330 Stack Processor
To install P330 stack processor firmware
1. From your S8300 telnet session, telnet back to the P330 stack processor:
Type
telnet <xxx.xxx.xxx.xxx>
where
<xxx.xxx.xxx.xxx>
is the IP address of the P330 stack master processor on the
customer’s LAN.
2. At the P330-1(configure)# prompt, type
copy tftp SW_image <file> EW_archive <ew_file>
<tftp_server_address> <Module#>
where
<file>
is the full-path name for the image file with format and vintage number
similar to viisa3_8_2.exe,
<ew_file>
is the full-path name for the embedded web application file with format similar
to p330Tweb.3.8.6.exe,
<tftp_server_ip_address>
is the IP address of the TFTP server, and
<Module#>
is the number, 1 through 10, of the media gateway in the stack. If there is only
one G700 media gateway, the number is
1
.
3. Verify that the download was successful when the prompt returns:
a. type
show image version <module #>
and check the version number in the
Version column for Bank B.