background image

 

 

SIMATIC RTLS4330G 

 

SIMATIC RTLS 

Localization systems 

SIMATIC RTLS4330G 

Operating Instructions 

 

 

09/2021 

C79000-G8976-C559-03 

Introduction 

 

 

Device description 

 

 

Installation & Operation 

 

 

Technical specifications 

 

 

Approvals 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for SIMATIC RTLS4330G

Page 1: ...LS4330G SIMATIC RTLS Localization systems SIMATIC RTLS4330G Operating Instructions 09 2021 C79000 G8976 C559 03 Introduction 1 Device description 2 Installation Operation 3 Technical specifications 4 Approvals 5 ...

Page 2: ...ly by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens prod...

Page 3: ... RTLS4330G and accessories 12 2 3 Pin assignment 13 2 4 LED status indicator 14 2 5 Dimension drawing 15 2 6 Troubleshooting 16 3 Installation Operation 17 3 1 Notes on installation 17 3 2 Mounting for ceiling mount 20 3 3 Mounting for corner and pole mount 21 3 4 Ethernet 22 3 5 Operation 22 3 6 Cleaning and maintenance 22 4 Technical specifications 23 5 Approvals 25 ...

Page 4: ...Table of contents SIMATIC RTLS4330G 4 Operating Instructions 09 2021 C79000 G8976 C559 03 ...

Page 5: ...ns These operating instructions apply to the following devices RTLS4330G CE article number 6GT2701 5EB03 Further documentation The system manual Commissioning SIMATIC RTLS provides information on other SIMATIC RTLS products that you can operate together with the devices in this product line in an Industrial Ethernet network You can find the system manual at the following link https support industr...

Page 6: ...ailable at more than 130 locations Courses can also be organized individually and held locally at your location You will find detailed information on the training curriculum and how to contact our customer consultants at the following Internet address https new siemens com global en products services industry sitrain personal html RTLS Technology and Practice ID RTLS TP Training and certification ...

Page 7: ...ons that are no longer supported and failure to apply latest updates may increase customer s exposure to cyber threats To stay informed about product updates subscribe to the Siemens Industrial Security RSS Feed under https www siemens com industrialsecurity Security recommendations General Note the following security recommendations to prevent unauthorized access Keep the firmware up to date Chec...

Page 8: ...a SysLog server to save all logs to a central location List of available protocols The following is a list of all available protocols and their ports through which the device can be accessed Table 1 1 List of available protocols Service Protocol Protocol port number Default port status Configurable port Authentication Encryption Ethernet IP TCP 1010 Open Yes No No Ethernet IP TCP 1011 Open Yes No ...

Page 9: ...oducts are low in harmful substances can be recycled and meet the requirements of the Directive 2012 19 EU for disposal of waste electrical and electronic equipment WEEE Do not dispose of the products at public disposal sites For environmentally compliant recycling and disposal of your electronic waste please contact a company certified for the disposal of electronic waste or your Siemens represen...

Page 10: ...Introduction SIMATIC RTLS4330G 10 Operating Instructions 09 2021 C79000 G8976 C559 03 ...

Page 11: ...nector for supply voltage and digital output Ethernet port Alternative power supply using Power over Ethernet PoE General The device is the home location for localization in the RTLS localization system It can be connected to the local IT infrastructure over Ethernet This connection sets up an exchange between the node the RTLS localization network and the Locating Manager server ...

Page 12: ...scope of delivery Article number Connecting cable for gateway Bulgin 400 Series Buccaneer PX0410 03S 3 pin 5 m 6GT2791 2AH50 Protective jacket IP65 for RJ45 connector made of plastic for cable mounting IP65 to gateway 6GT2790 0CB00 Holder for gateways for ceiling mounting 6GT2790 0BE20 Holder for gateways for corner and mast mounting 6GT2790 0BE30 IE TP Cord RJ45 RJ45 4 x 2 1 m 6XV1870 3QH10 3 m 6...

Page 13: ... the Ethernet cable ensure that the twist lock connectors are correctly secured Figure 2 1 RJ45 connector Amphenol LTW PCP 00AMMA TLM7001 Plug in connector for power digital output 3 pin plug in connector Buccaneer PX0412 03P Connectors SA3350 1 Sealing cover PX0480 The pins are occupied as illustrated below Pin Description 1 Supply voltage red 8 30 V DC 2 Digital output brown Switched input volta...

Page 14: ...evice RADIO LED Off when the radio signal of the device to other gateways or transponders is inactive RADIO LED Flashes yellow when the radio signal of the device to other gateways or transponders is active LAN SERVER LED Lights up blue when the device has an Ethernet connection and a connection to the Locating Manager LAN SERVER LED Flashes blue once per second when the device has an Ethernet con...

Page 15: ...cription 2 5 Dimension drawing SIMATIC RTLS4330G Operating Instructions 09 2021 C79000 G8976 C559 03 15 2 5 Dimension drawing Figure 2 2 Dimension drawing SIMATIC RTLS4330G All dimensions specified in millimeters ...

Page 16: ...ooting Device does not respond all LEDs are off The device is not connected or the power supply unit is not switched on Check the supply voltage of the device The blue LED LAN SERVER is off Device has no Ethernet connection Check local network Check firewall The blue LED LAN SERVER flashes once per second Device is not connected to the Locating Manager Enable Locating Manager ...

Page 17: ... trouble free installation and commissioning The devices can only be used in conjunction with the RTLS localization system The device is intended for fixed installation on walls or ceilings Installation is to be performed by qualified and trained users according to the operating instructions In addition installation must take place in accordance with the respective instructions for the installatio...

Page 18: ...rom penetrating moisture by closing off connectors that are not in use with suitable covers These covers are installed on the device Supply voltage When the supply voltage is connected to the power plug all LEDs flash briefly for a moment The RUN LED lights up as soon as voltage is present You can supply the device with power via the Ethernet cable In this case the power plug must be tightly seale...

Page 19: ... without holder to the wall 1 Draw the bore holes on the wall according to the following drilling pattern 2 Drill the holes with a suitable device 3 Insert the suitable anchors in the holes Anchors are not supplied with the device 4 Mount the device to the wall using screws 4 mm Screws are not supplied with the device Figure 3 1 Drilling pattern All dimensions specified in millimeters ...

Page 20: ...he ceiling 2 Drill the holes with a suitable device 3 Insert the suitable anchors in the holes Anchors are not supplied with the device 4 Mount the mounting plate to the ceiling 5 Install the device to the mounting plate using the screws M4 Use the enclosed plastic screw for the upper opening on the rear of the device and the metal screws for the fixings at the bottom of the device Screws are supp...

Page 21: ...es on the corner mast 2 Drill the holes with a suitable device 3 Insert the suitable anchors in the holes Anchors are not supplied with the device 4 Install the universal support to the corner mast 5 Mount the device to the universal support using the screws M4 Screws are supplied with the device Figure 3 3 Universal support all dimensions specified in millimeters Note If drilling is not possible ...

Page 22: ...uitable for operation in hazardous areas Operation of the system according to EN 62368 1 is only safe when the housing cover is installed cooling fire protection interference suppression In case of emergencies e g when the enclosure is damaged when liquids or foreign objects are entering the device the device must be disconnected from the power supply and maintenance must be contacted immediately ...

Page 23: ...4800 MHz CE 6000 MHz 7000 MHz CE Transmit power 0 037 mW 41 3 dBm MHz Range Maximum 30 m Accuracy of the localization typical 0 2 m Antenna Built in UWB antenna CHIRP radio frequencies Wireless method IEEE 802 15 4a Chirp Spread Spectrum CSS Transmission speed 1 Mbit s Operating frequency rated value 2400 2480 MHz Bandwidth 80 MHz Frequency range 2400 MHz 2483 5 MHz Transmit power Maximum 100 mW c...

Page 24: ... Permitted ambient conditions Ambient temperature 15 50 C Design dimensions weights and connectors Dimensions L x W x H 180 x 180 x 48 mm Weight 600 g Degree of protection IP65 Method of securing Fixed mounting on walls or ceilings Enclosure Plastic enclosure ASA and PC Color Titanium gray Power plug 3 pin plug in connector with screw type terminal Bulgin Buccaneer PX0412 03P Ethernet RJ45 Etherne...

Page 25: ...azardous substances in electrical and electronic equipment official journal of the EU L174 1 July 2011 pages 88 110 Radio Equipment Directive 2014 53 EU RED Directive of the European Parliament and of the Council of 16 April 2014 on the harmonization of the laws of the member states relating to placing radio equipment on the market official journal of the EU L153 22 May 2014 pages 62 106 RoHS dire...

Page 26: ...ices Part 17 Specific conditions for broadband data transmission systems ETSI EN 301 489 33 Electromagnetic compatibility and radio spectrum matters ERM Electromagnetic compatibility for radio equipment and services Part 33 Special conditions for ultra wideband UWB devices EN 55011 Industrial scientific and medical equipment Radio frequency disturbance characteristics Limits and methods of measure...

Page 27: ...eration with a directly connectable safety extra low voltage SELV from a limited power source LPS The power supply therefore needs to meet at least one of the following conditions Only safety extra low voltage SELV with limited power source LPS complying with IEC 60950 1 EN 60950 1 VDE 0805 1 or IEC 62368 1 EN 62368 1 VDE 62368 1 may be connected to the power supply terminals The power supply unit...

Page 28: ...lectrique doit par conséquent satisfaire au moins à l une des conditions des conditions suivantes On veillera par conséquent à ne connecter aux bornes d alimentation qu une très basse tension de sécurité TBTS à puissance limitée Limited Power Source LPS selon CEI 60950 1 EN 60950 1 VDE 0805 1 ou CEI 62368 1 EN 62368 1 VDE 62368 1 Le bloc d alimentation de l appareil doit être conforme à NEC Class ...

Reviews: