![AV-GAD EasyLoader AV-2016D Installation And Operation Manual Download Page 34](http://html1.mh-extra.com/html/av-gad/easyloader-av-2016d/easyloader-av-2016d_installation-and-operation-manual_3023938034.webp)
34
SECTION IV: PROGRAMMING
1. SYSTEM CODES
Up to sixteen different Arm/Disarm codes and one installer (dealer) code are available; each code
consists of 1 to 6 digits.
Do not use ‘0’ as the first digit in a code.
Do not use ‘5’ as first digit in a code number if
Instant Arming via key 5
was programmed.
User code must not start with the same numbers as the installer programming code (1994).
Do not use same codes or same first digit for different codes. For example if code No .1 is 1234,
programming code No. 2 cannot be 1256.
1.
Default Arming and Disarming Code ‘1 2 3 4’
(Code No. 1) - Use ‘1234’ as Arming
Code (also called Owner Code). Use code No. 1 to program a new user code.
Upon setting new Arming & Disarming code, default user code ‘1234’ automatically
replaced.
For setting default codes, Power up by applying AC and battery and immediately
(during 20 seconds) hold-down keys
*
#
Press both
together
after 2
nd
beep, release keys, ‘U’
displayed three times in confirmation. To set codes to default during programming; in
address, 200 enter 05, all codes will restore to default.
2.
Code number 7 for access control
(requires programming) - Arm/Disarm code No. 7
activates the SLO (Selective Output) output, which is used for such functions as opening an
electric lock.
Code number 7 is operative during both, ARM and DISARM modes, confirmed by seven
short beeps. Code 7 drives the SLO output as ‘Momentary’ output.
Pulse duration is 5 seconds.
3.
Code number 8 as Visitor
Code
(requires programming) - Arm/Disarm code No. 8 is for
‘one time code’ (employees and one-time visitors). This code is valid for 30 seconds from
Arming. After 30 seconds, the code is rendered as invalid.
Entering code 8 will delete zone bypasses, including auto-bypass.
4.
Code number ‘9’,
Programming Code (Installer Code)
- Code No. 9 enables entering the
programming mode (system features programming) at the Installer level.
The factory default programming code is ‘1 9 9 4.’
The programming code may be installer-programmed. Installer code does not Arm or Disarm
system.
5.
User Codes
- (Arming and Disarming code). Each code consists of 1 to 6 digits. System
provides eight user programmable codes.
6.
Key Visual Feedback -
Visual ‘feedback’ from the keypad display upon entering of code.
This feature indicates the code entry progress and is most practical when the keypad buzzer is
disabled at Group Bypass mode, or if selected by programming. Entry of code by user or
installer is confirmed at keypad display. Display segments will light up clockwise, indicating
the sequence of the digits entered.
Typing six erroneous codes will lock the keypad keys for 30 seconds