![AV-GAD EasyLoader AV-2016D Installation And Operation Manual Download Page 20](http://html1.mh-extra.com/html/av-gad/easyloader-av-2016d/easyloader-av-2016d_installation-and-operation-manual_3023938020.webp)
20
Dialing mode is programmable (refer to programming sheet addresses 088 and 089).
Connect the telephone line to ‘TEL-LINE’ terminal, if handsets connected to same line connect
them to ‘PHONES’, when system attempt to dial the ‘PHONES’ disconnected. Do not connect
to ISDN or other digital telephone system. Most ISDN converters have an Analog line; connect
the Analog line of the ISDN the TEL-LINE terminal. Option: To protect your line add the Tele-
Spy, it is a 24H telephone line monitor separate module. Note: To perform telephone line test
enable Dial Tone detection at address 083.
For AUSTEL installations: At address 074 enter 8, at address 087 enter 2 (maximum), don’t
connect any phones in parallel with TEL-LINE terminal. Software Dial Tone telephone monitor
is included, refer to address 094, 076 options 5,6. Dialing problems may occur when system
telephone line is connected to Telstra Duet system or similar.
4.6
SVM – Voice module
The
SVM-40
and
SVM-60
speech modules allow the recording and playback of two messages,
with optional playback through an external speaker (not included). SVM-40 message duration is
40 seconds; SVM-60 message duration is 60 seconds. The SVM contains an on board
microphone.
The
SVM
is a
high technology device, electronically stores messages with or without power.
The
SVM
is as a digital message source in Series 2000 Alarm Control Panels, telephone dialers
or in other applications. The
SVM
supplied audio is capable to drive audio amplifier, message
center, automatic dialer or other device.
When connected to Series 2000 Alarm Control Panels, program the SVM option (at
programming table 072-7). Follow the wiring procedures (included in SVM manual) simulate
alarm, the panel will dial first the Communicator telephone number (telephone number 2 and 3),
then dial to other programmed numbers.
After dialing, the panel will trig the SVM to send the recorded message. If address 071 (1) is
programmed Telephone 1 is erased within arming and disarming.
4.7
Remote Key and Wireless Arming & Disarming
•
The AV-2055D, 2088D, 2016D enables Arming/Disarming by remote momentary or latch
key-switch (as programmed in address 071), which is connected to terminals ‘KE’ and ‘- Aux.
Power’.
•
When using remote key-switch, wire length should not exceed 10 meters.
•
A Momentary pulse (momentary trig) between ‘KEY’ and ‘-V’ terminals will Arm and
Disarm the control panel. (Before arming close ‘instant’ and ‘24H’ zones)
•
System reverts to previous status with next momentary pulse. (Refer to AV-2016 Wiring
Diagram.)
•
Arming by key will cause a long beep at the keypad if "Enable two siren beeps at disarm"
(073 - 6) is programmed.