After Automatic Arming is programmed, the system time can be set only via User Programming
Mode: Enter User Programming Mode (hold-down 8 and 1234), hold down '1' ('t' is displayed)
and type hour and minutes. Hold down key '1' and wait for the time display. Holding down keys
'0' then '1' (in use mode) to program the time is possible only if the Automatic Arming is
disabled (otherwise an 'Error’ warning is displayed). Those settings procedure at PRO panels is
different; refer to the AV-706/7 keypad manual.
Automatic Arming will not operate if the system time has not been set (blinking 'h'). Automatic
Arming will not operate if the control panel is already armed.
Automatic Arming will operate even if the control panel is currently in alarm.
When the Automatic Arming programmed time arrives, the system starts at a 30-second
countdown. An 'A' is intermittently displayed and beeps are sounded at the keypad.
During the countdown period, to abort Automatic Arming enter a valid user code (not code No.
7, if used to ‘open’ a door).