Warning: The remote indications are capable of driving maximum 300 mA, overloading
or ap12V to the remote indications is dangerous and not assured by warranty
To drive a low current Strobe Light (Xenon) consuming up to 300 mA, connect the strobe to
SLO.
Beginning with version 2.08, a new feature enables programming the listed outputs to supply
float output (0V) during alarm and -V at ideal. Refer to address 073-8.
In case other features selected for the same output, this feature is not applicable.
When connected a relay the remote indication, connect a diode must to the relay coil in reserve
polarity to the supplied voltage, or use AV-01/02 relay module. For LED driving, connect a
2.2K resistor in series.
Hardware Tests for Outputs
(starting version 2.17)
This feature enables testing of devices connected to the remote indications.
In programming mode, using 200 + commands (SLO1 exist only in AV-2016 panels):
30 - On Output: ON
31 - On Output: OFF
32 - A1 Output: ON
33 - A1 Output: OFF
34 - A2 Output: ON
35 - A2 Output: OFF
36 - SLO Output: ON 37 - SLO Output: OFF
38 - SLO1 Output: ON
39 - SLO1 Output: OFF
40 - SPARE Output: ON 41 - SPARE Output: OFF
PRO only: 42/43 LCD display - Display pattern test
3.3
Wiring and Connection of Relay Module
The Relay Module enables connection of
EasyLoader
2000 Series panels to most types of Bells
and self-contained internal battery Bells or Sirens (the term ‘Bell’ will apply to both Bells and
Sirens).
Trigger the Relay Module via the siren output of the control panel. The power which drives the
Bell may be supplied either from the Aux. Power of the control panel, or from an external power
supply in case the Bell requires higher current than the 0.7A supplied by the control panel.
Full installation details enclosed with the relay module.
4. WIRING AND POWERING UP
4.1
Grounding – Lightning Protection
The control panel must be earth grounded for lighting protection to work effectively, and in
order to prevent RFI and EMI interfaces. Attach the ground connection to a verified cold-water