![AV-GAD EasyLoader AV-2016D Installation And Operation Manual Download Page 30](http://html1.mh-extra.com/html/av-gad/easyloader-av-2016d/easyloader-av-2016d_installation-and-operation-manual_3023938030.webp)
30
1.4
LED Indicators
AV-701 and AV-702 Keypads: Four LEDs provide visual indication of System status, as well as
confirmation of various modes.
Keypad LED’s indication
Armed Led-Red
AV-2016
AV-2016DP
Off
System Disarmed
All partitions Disarmed
Blink slowly
An alarm is triggered
At least one partition is armed
ON steady
System Armed
All partitions are ARMED
Blink fast
Mode does not exist
Alarm triggered in partition/s
Status LED-Green
AV-2016
AV-2016DP
Off
System Disarmed
Some partitions are Armed
Blink slowly
Some zones are open
Some zones are open
ON steady
All zones OK
All zones OK
Blink fast
Some zones have been tampered Some zones have been tampered
Shunt LED-Orange AV-2016
AV-2016DP
ON steady
Some zones are bypassed
Some zones are bypassed
Blink slowly
Group bypass entered
Group bypass in some partition
Blink slowly
8 seconds after Armed with
Group Bypass
8 seconds after Armed with
Group Bypass
Fire LED-Red
AV-2016
AV-2016DP
Blink slow
Warning before Fire alarm
Warning before Fire alarm
Blink fast
During and after Fire alarm
During and after Fire alarm
Note: Troubled Zones during alarm displayed at the Keypad.
Red ARMED/ALARM Indicator
- Lights up when system is armed, and blinks after an
alarm is triggered at any zone. Blinking indicates alarm history in memory.
Green STATUS Indicator
– The Green LED Blinks when zone/s are troubled and remains
lit as long as zones are clear, rapid blinking during Tamper alarm.
Yellow SHUNT (Bypass) Indicator
- Lights up upon zone bypass.
(Note: may light automatically upon arming if Auto Bypass was programmed).
The indicator also lights up and blinks if a Group Bypass was entered by pressing ‘0’ twice.
Red FIRE (Trouble) Indicator
- Rapid blinking when a Fire Zone is troubled.
Two LEDs Flashing (Left Most LEDs)
- In user code programming mode, rapid blinking
indicates code or code index to be entered. In Installer programming mode, it indicates address
entry.
In Disarmed mode, the two left-most LEDs bl zone number display indicate 24H-alarm
mode.