46
Remarks: yellow and green cord should be connected to connection point with
mark.
z
Fasten the fixture of wire to control panel.
z
Screw up the control panel cover to its original place.
Test running
z
Make sure that the pipes and wires are connected.
z
Make sure that both the liquid valve and gas valve on the side are completely open.
1.
The connection of power source
¾
Connect the wire to independent power source socket.
¾
Preparation of remote control.
¾
Run the air-conditioner in cooling operation mode for 30 minutes or longer.
2.
Performance evaluation
¾
Test the out and in air temperature.
¾
Make sure that the temperature difference between the out and in air is greater than 8
o
C.