5
70 detachable cool series
. Heating
After the power supply is switched on, the machine is set to HEAT
mode and the coil of the electromagnetic four-way valve is energized.
After the compressor starts to operate, the high-temperature and
high-pressure refrigerant gas first comes into the heat exchanger of the
indoor unit, where it is cooled, releases heat and increases the room
temperature. The cooled high-pressure refrigerant is then throttle1d in the
outdoor unit and returns to the compressor after evaporation. With such
cycles being maintained, the objective of increasing the room temperature
is fulfilled.