4
Chapter 2 Operating Principle
. Cooling
After the power supply is switched on, the machine is set to COOL
mode. With the compressor being operated, the low-temperature and
low-pressure refrigerant vapor is sucked into the compressor where it is
turned into high-temperature and high-pressure gas. Then it is cooled
down in the outdoor heat exchanger by the air and becomes liquid. After
being throttled by the capillary, the refrigerant liquid comes into the
indoor unit and then it evaporates in the indoor heat, exchanger,
absorbing heat and reducing the room temperature. The evaporated
refrigerant vapor returns to the outdoor unit and is again sucked into the
compressor, completing the cycle. With the refrigerant cycling being kept
on, the objective of lowering the room temperature is fulfilled.
60 detachable cool series