8. Serial Communication Commands
70
© Copyright Reserved Autonics Co., Ltd.
POS
It acquires the current position point and returns a position coordinate point.
Format
Command [CR]
POS[CR]
Response :
• For 2-axis
POS , [CR]
Current position of Y-axis(pulse)
Current position of X-axis(pulse)
The response for the current position pulse count is composed of hexadecimal.
• For 1-axis
POS [CR]
Current position of X-axis(pulse)
The response for the current position pulse count is composed of hexadecimal.
HOM
It carries out the Home Search of the specified axis.
Format
Command
[Axis specification] [CR]
HOM X [CR]
Y
Put the axis specification "X" in case of PMC-1HS.
[Example] • To carry out Home Search of X and Y axes at the same time, for 2-axis
HOM [XY [CR]
• To carry out Home Search for 1-axis
HOM [X[CR]
Response: No-response
STO
It decelerates to stop the drive of the specified axis.
However, when the drive speed is lower than the start speed, the drive stops immediately.
Format
Command
[Axis specification] [CR]
STO
X [CR]
Y Setting an axis operates with arrangement.
Put the axis specification "X" in PMC-1HS.
[Example] • To decelerate for stop of X and Y axes in 2-axis
STO
XY [CR]
• To accelerate for stop for 1-axis
STO
X [CR]
Response : No-response