3. Configuration of the Operating Mode and System Parameters
12
© Copyright Reserved Autonics Co., Ltd.
3.2.6
Software Limit
Select Enable or Disable for the Software Limit.
Display
Selection
Default value
Software Limit
Disable/ Enable
Disable
The Software Limit is the overrun limit function that can be configured by internal position data apart from
the mechanical limit signal input by means of external sensor. The Software Limit is selectively configured
as the parameter values at the both of + and - directions. When it is enabled and exceeds the range of soft
limit + or -, the controller is decelerated to stop. To cancel the software limit, drive the controller toward the
reverse direction of the error.
【
Reference
】
Even if the Software Limit is enabled, the controller is not worked in operating the Home
search command.
3.2.7
Power on Home Search Start
When the power is turned on, select Enable/Disable for the auto-start of home search.
Display
Selection
Default value
Power On Home Search Start
Disable / Enable
Disable
The Power on Home Search Start is the function to search home automatically when the power is turn on or
the main body is reset.
3.2.8
Power on Program Start
When the power is turned on, select Enable/Disable for the auto-start of the program.
Display
Selection
Default value
Power On Program Start
Disable / Enable
Disable
The Power on Program Start is the function to execute the program configured as the start of the program
register 00(REG00) when the power is turned on or the main body is reset. If the Power on Program Start is
enabled, the program is automatically started after the completion of Home Search.
【
Caution
】
(1)For the use of the Power on Program Start, let the next command is execute after the specified time by
using the timer command(TIM) to REG00. In addition, it is recommended to configure the Home Search
command for return-to-the origin to the program.
(2)To cancel the Power on Program Start or the Power on Home Search Start, change the mode setup to
Disable after stopping the operation(press the Stop key on the main screen).
Do not change the mode in operating.
(3)Do not edit the program or change modes or parameters while the program is operated by the Power on
Program Start. Change after the program is closed on the main screen(press the Stop key).
Warning
When the Power on Home Search Start is configured, note that the personnel injury may be resulted.