3. Configuration of the Operating Mode and System Parameters
14
© Copyright Reserved Autonics Co., Ltd.
3.3.3
Deceleration Rate
The deceleration rate is a parameter is to be an acceleration speed when an adjustable speed drive acceler
-
ates.
Display
Setting range
Default value
Deceleration Rate
1 ~ 8000
400
Deceleration Rate(pps) = D × 125 × Speed multiplier,
D is the Deceleration value configured.
Since the default mode of the Deceleration Value is Accel, the acceleration value is used in deceleration and
symmetry adjustable speed drive is operated. To operate asymmetry adjustable speed drive, configure the
mode of the Deceleration Value as Decel.
3.3.4
Start Speed
The start speed means the speed when the adjustable speed drive starts or the end speed.
Display
Setting range
Default value
Start Speed
1 ~ 8000
50
The actual start speed is the value that is the start speed configuration value (SV) and the speed multiplier
is multiplied.
Start speed(pps) = SV × Speed multiplier
If the drive speed is bigger than the start speed, the adjustable speed drive is operated.
In this case, the parameter for the adjustable speed must be configured. If the drive speed is smaller than
the start speed, the drive does not operate at adjustable speed but at constant speed from the first. Home
Search High Speed is, also, operates in the same way.
3.3.5
Drive Speed 1~4
The drive speed is the speed for an adjustable speed drive.
Display
Setting range
Default value
Driver Speed 1
1 ~ 8000
10
Driver Speed 2
1 ~ 8000
100
Driver Speed 3
1 ~ 8000
1000
Driver Speed 4
1 ~ 8000
8000
Four-type drive speed for each axis is configured. For driving, one of four speeds is selected. The actual
drive speed is the value that drive speed configuration value(V) and speed multiplier are multiplied.
Drive speed(pps) = V × Speed multiplier
If the drive speed value is bigger than the start speed value, the drive operates at adjustable speed.
In this case, the parameter for the adjustable speed must be configured. If the drive speed is smaller than
the start speed, the drive does not operate at adjustable speed but at constant speed from the start.
3.3.6
Post Timer 1~3
The post timer is the waiting time to start next command after the execution of a drive command such as
ABS or INC for program operation.
Display
Setting range
Default value
Post Timer 1
1 ~ 65535
10
Post Timer 2
1 ~ 65535
100
Post Timer 3
1 ~ 65535
1000