3
Modbus Mapping Table
© Copyright Reserved Autonics Co., Ltd.
41
3.4.1.4
CH4-S2UI-2
No(Address)
Func
R/W Parameter
Description
Set range
Unit Default Note
400151 (0096)
03/06/16 R/W CH4 Input Set
Copy
CH4 copy input
parameter
Refer to channel
table.
※
4
-
None
400152 (0097)
03/06/16 R/W CH4 Pen Record CH4 display and record
measuring value
0:OFF, 1:ON
-
ON
400153 (0098)
03/06/16 R/W CH4 Pen Color CH4 record color
0:Violet, 1:Red,
2:Gray, 3:Green,
4:Blue, 5:Brown
-
Automati
c
set(CH1
to CH6)
(CH7 to
CH12)
Specify color.
400154 (0099)
03/06/16 R/W CH4 Record
Zone
CH4 record zone
0:None, Zone1 to
Zone n
-
Zone(1to
N)
400155 (009A)
03/06/16 R/W CH4 Tag Name CH4 channel name
1 to 6 characters
-
"CH-
□□"
400156 (009B)
400157 (009C)
400158 (009D) 03/06/16 R/W CH4 Input Type CH4 input specification
Refer to input type
table.
※
5
-
TC-K
400159 (009E) 03/06/16 R/W
CH4
Range/Scale
Point
CH4 decimal point
0:0, 1:0.0, 2:0.00,
3:0.000, 4:0.0000
-
Range
which
has
decimal
point
- TC/RTD type:
only available
0, 0.0
- Analog type:
Supports all. But
for Two Unit,
available 0:0,
1:0.0, 2:0.00
400160 (009F) 03/06/16 R/W
CH4
Temp/Display
Unit
CH4 temperature unit
(300209) Refer to
address.
-
℃
- TC/RTD type:
0:
℃
, 1:
℉
, 2:
˚K
-Analog type:
Supports all.
400161 (00A0) 03/06/16 R/W
CH4 Low
Range/Low
Graph Scale
※
7
CH4 lower limit input
value/CH4 lower limit
graph scale value
Min. value of sensor
input range to upper
limit input value/ Upper
limit graph scale value
- F.S 5%
-
-200
Refer to range
decimal point set
table.
※
6
400162 (00A1) 03/06/16 R/W
CH4 High
Range/High
Graph Scale
※
7
CH4 upper limit input
value/CH4 higher limit
graph scale value
Lower limit input value/
lower limit graph scale
value + F.S 5%) to
Max. sensor input
range
-
1350.0
400163 (00A2)
03/06/16 R/W CH4 Low Scale CH4 analog lower limit
scale value
-99999 to 99999
Digit 0.0
Applied
depending on
the number of
decimal point of
CH4
Range/Scale
Point.
Ex) When scale
pointer value is
0.0, if inputting
9999, it is
recognized as
999.9
400164 (00A3)
400165 (00A4)
03/06/16 R/W CH4 High Scale CH4 analog upper limit
scale value
-99999 to 99999
Digit 100.0
400166 (00A5)
400167 (00A6) 03/06/16 R/W CH4 Special
Function
CH4 special function
TC/RTD input: 0:None,
1:Difference
Analog input: 0:Linear,
1:Root, 2:Square,
3:Two Unit
-
None
400168 (00A7) 03/06/16 R/W Two Unit
Two Unit conversion
value
1 to 35
Digit 3
If 100 is set, it is
recognized as
1.00.
400169 (00A8) 03/06/16 R/W CH4 Ref
Channel
CH4 reference channel
Refer to channel
table.
※
4
-
None
400170 (00A9) 03/06/16 R/W CH4 Input Bias CH4 error correction
-9999 to 9999
Digit 0000
Uses correction
value which
applies scale
decimal point.
400171 (00AA) 03/06/16 R/W CH4 Span
CH4 gradient adjustment 0.100 to 5.000
Multipl
e
1.000
If 1000 is set, it
is recognized as
Summary of Contents for krn100 series
Page 1: ...Preface Copyright Reserved Autonics Co Ltd i USER MANUAL For COMMUNICATION ...
Page 2: ...ii Copyright Reserved Autonics Co Ltd ...
Page 10: ...Table of Contents x Copyright Reserved Autonics Co Ltd ...
Page 18: ...1 Modbus RTU protocol 18 Copyright Reserved Autonics Co Ltd ...
Page 82: ......