3
Modbus Mapping Table
© Copyright Reserved Autonics Co., Ltd.
45
3.4.1.6
CH6-S3UI-2
No(Address)
Func
R/W Parameter
Description
Set range
Unit Default Note
400251 (00FA) 03/06/16 R/W CH6 Input Set
Copy
CH6 copy input
parameter
Refer to channel
table.
※
4
-
None
400252 (00FB) 03/06/16 R/W CH6 Pen Record CH6 display and record
measuring value
0:OFF, 1:ON
-
ON
400253 (00FC) 03/06/16 R/W CH6 Pen Color CH6 record color
0:Violet, 1:Red,
2:Gray, 3:Green,
4:Blue, 5:Brown
-
Automati
c
set(CH1
to CH6)
(CH7 to
CH12)
Specify color.
400254 (00FD) 03/06/16 R/W CH6 Record
Zone
CH6 record zone
0:None, Zone1 to
Zone n
-
Zone(1
to N)
400255 (00FE)
03/06/16 R/W CH6 Tag Name CH6 channel name
1 to 6 characters
-
"CH-
□□"
400256 (00FF)
400257 (0100)
400258 (0101) 03/06/16 R/W CH6 Input Type CH6 input specification
Refer to input type
table.
※
5
-
TC-K
400259 (0102) 03/06/16 R/W
CH6
Range/Scale
Point
CH6 decimal point
0:0, 1:0.0, 2:0.00,
3:0.000, 4:0.0000
-
Range
which
has
decimal
point
- TC/RTD type:
only available
0, 0.0
- Analog type:
Supports all. But
for Two Unit,
available 0:0,
1:0.0, 2:0.00
400260 (0103) 03/06/16 R/W
CH6
Temp/Display
Unit
CH6 temperature unit
(300209) Refer to
address.
-
℃
- TC/RTD type:
0:
℃
, 1:
℉
, 2:
˚K
-Analog type:
Supports all.
400261 (0104) 03/06/16 R/W
CH6 Low
Range/Low
Graph Scale
※
7
CH6 lower limit input
value/CH6 lower limit
graph scale value
Min. value of sensor
input range to upper
limit input value/ Upper
limit graph scale value
- F.S 5%
-
-200
Refer to range
decimal point set
table.
※
6
400262 (0105) 03/06/16 R/W
CH6 High
Range/High
Graph Scale
※
7
CH6 upper limit input
value/CH6 higher limit
graph scale value
Lower limit input value/
lower limit graph scale
value + F.S 5%) to
Max. sensor input
range
-
1350.0
400263 (0106)
03/06/16 R/W CH6 Low Scale CH6 analog lower limit
scale value
-99999 to 99999
Digit 0.0
Applied
depending on
the number of
decimal point of
CH6
Range/Scale
Point.
Ex) When scale
pointer value is
0.0, if inputting
9999, it is
recognized as
999.9
400264 (0107)
400265 (0108)
03/06/16 R/W CH6 High Scale CH6 analog upper limit
scale value
-99999 to 99999
Digit 100.0
400266 (0109)
400267 (010A) 03/06/16 R/W CH6 Special
Function
CH6 special function
TC/RTD input: 0:None,
1:Difference
Analog input: 0:Linear,
1:Root, 2:Square,
3:Two Unit
-
None
400268 (010B) 03/06/16 R/W Two Unit
Two Unit conversion
value
1 to 35
Digit 3
If 100 is set, it is
recognized as
1.00.
400269 (010C) 03/06/16 R/W CH6 Ref
Channel
CH6 reference channel
Refer to channel table.
※
4
-
None
400270 (010D) 03/06/16 R/W CH6 Input Bias CH6 error correction
-9999 to 9999
Digit 0000
Uses correction
value which
applies scale
decimal point.
400271 (010E) 03/06/16 R/W CH6 Span
CH6 gradient adjustment 0.100 to 5.000
Multipl
e
1.000
If 1000 is set, it
is recognized as
Summary of Contents for krn100 series
Page 1: ...Preface Copyright Reserved Autonics Co Ltd i USER MANUAL For COMMUNICATION ...
Page 2: ...ii Copyright Reserved Autonics Co Ltd ...
Page 10: ...Table of Contents x Copyright Reserved Autonics Co Ltd ...
Page 18: ...1 Modbus RTU protocol 18 Copyright Reserved Autonics Co Ltd ...
Page 82: ......