Parameter
Min
Max
Default
Step
Unit
Menu
No.
Safety Close Mode
OFF On
On
6.1
PE Beams INPUT RESPONSE MODE Sets the P.E
response mode. Options are OPEN and CLOSE
cycles stop, Close cycles stop or Close cycle reverse
OPN & CLS stop
CLS to stop
CLS to reverse
CLS to
reverse
6.2
PE REVERSE TIME
5
FULL
FULL
1
Sec
6.3
PE TYPE EasyBeam™ or three wire supported
EasyBeam™
3 WIRE
EasyBeam™
6.4
GPI INPUT MODE confi gure the GPI input. Options
are OSC, PED and DAY LIGHT SAVING
OSC, PED,
DST
OSC
6.5
PED INPUT = SWIPE MODE Selects PED input
functions as pedestrian access swipe input
Off On
Off
6.6
OPN INPUT N/C OPERATION
Selects operating polarity of OPN input
Off
On
Off
6.7
OPN I/P = 2ND PE BEAMS OPERATION
Confi gure OPN input to take 2ND PE BEAMS
Off
On
Off
6.8
STP INPUT N/C OPERATION
Selects operating polarity of STP input
Off
On
Off
6.9
FIRE INPUT N/C OPERATION
Selects operating polarity of FIRE input
Off
On
Off
6.10
FIRE INPUT MODE confi gure the fi re input. Options
are OPN, CLS and PED
OPN,
CLS,
PED
OPN
6.11
REMOTE CODE ENABLED
Selects remote transmitter coding function
Off On
On
6.12
ACTIVITY REPORTS Select report to be output
Off
255
Off
1
6.13
ACTIVITY REPORT ID
Selects ID for controller, sent with activity report
0
65535
0
1
6.14
VACATION MODE
Selects Vacation Mode - disables remote control
Off On
Off
6.15
PASSWORD
Selects password protection for all changes
Off On
Off
6.16
Transmitter Grouping
Off
On
Off
6.17
Fault Auto Reset
Selects Fault Auto Reset
Off
On
Off
6.18
LED Low Power Mode
Selects saving the power by turning LEDs Off
Off
On
Off
6.19
Console OSC Buttons
Selects to lock out the console buttons
Off
On
On
6.20
AUX OUT O/P can be activated by either LIGHT
DRIVE ,CLOCK/TXER ,OPEN or CLOSE status
LIGHT
DRIVE
6.21
Control Board Adjustments