28
Axess® Pro Series 3000
Owner Installation Instructions
Control Board Adjustments
If the door is moving, the activation of the GPI input or by a transmitter button with the OSC function assigned
will cause the door to stop. The next trigger will move the door in the opposite direction to the last travelled.
When GPI Input Is Confi gured As PED:
The activation of the GPI input or by a transmitter button with PED function assigned will open the door partially
to allow pedestrian access but prevent vehicle access. The position the door is driven to is automatically set to
halfway during setting of the travel limits, but can be adjusted to suit.
When GPI Input Is Confi gured As DST:
The GPI input can be used to switch between STD time and DST (daylight savings time). The time selected is the
amount of time added to STD time when DST is selected. The Options are OFF, 30, 60, 90 or 120 minutes. The
GPI input needs to be constantly active to show day light saving time.
Menu 6.6 PED Input Function
If GPI or Fire Input is selected as PED then these inputs can be confi gured to a SWIPE type input for pedestrian
access. This provides full functionality with the PE Beams Triggered Pedestrian Auto-Close function.
Menu 6.7 Open Input Polarity
The OPN input is normally confi gured for N/O operation. This parameter allows its operation to be changed to
N/C.
Menu 6.8 Open Input As A Second PE Beams Input
Selecting this parameter will allow the OPN input to be used as a second PE Beams input. When the OPN input
is active, the door is prevented from being closed. If the OPN input is triggered while the door is closing, the
controller will stop the motor and then open the door. The OPN input has no effect while the door is opening.
The second PE Beams (OPN) input must be active when the PE Beams input is activated in order for PE Beams
Triggered Auto-Close to be activated.
Menu 6.9 STP Input Polarity
The STP input is normally confi gured for N/O operation. This parameter allows its operation to be changed to
N/C.
Menu 6.10 FIRE Input Polarity
The FIRE input is normally confi gured for N/O operation. This parameter allows its operation to be changed to N/C.
Menu 6.11 FIRE Input Confi guration
Fire input can be confi guration as OPN ,CLS (available only if PE Beams are installed) or PED function.
Activated by FIRE input terminal with N/O or N/C (if selected) switch.
When Fire Input Is Confi gured As CLS :
Activating the fi re input will cause the door to close only if PE Beams are installed. Holding the input active will
prevent door from opening.
When Fire Input Is Confi gured As PED:
The activation of fi re input will open the door partially to allow pedestrian access but prevent vehicle
access. The position the door is driven to is automatically set to halfway during setting of the travel limits,
but can be adjusted to suit.
When Fire Input Is Confi gured As OPN :
Activating the fi re input will cause the door to open. Holding the input will prevent the door from closing.
6.12 Remote Code
The controller supports the Remote Code Set feature. This parameter can be used to disable the feature for security
or transmitter management reasons.