Menu 5. Motor Settings
Motor Speed
The speed of the motors run at is controlled by the OPEN AND CLOSE SPEED FREQUENCY parameter. The
default value is the maximum recommended for normal operation. If however the door moves too quickly or
slowly for a particular installation, the frequency can be reduced or increased to make the motors run slower or
faster.
NOTE:
Altering these parameters will cause the travel limits to be cleared.
Motor Speed Control - SOFT START/SOFT STOP
The motor’s speed is microprocessor controlled, ramping up speed as the door starts to move, and ramping
down as it approaches the travel limits to provide a gentle stop.
Menu 6. Operating Modes
Menu 6.1 Safety Close Mode
By enabling this parameter, the user can close the door only by holding the close button on the wall control unit or by
holding the CLS input active. The door can not be closed by Auto-Close or by transmitters. If the PE Beams are not
installed, the controller will be loaded with Safety Close Mode and the following message will be displayed:
ATTENTION! “SAFETY CLOSE MODE has been enabled as no P.E beam has been
installed! This means that the door can only be closed by HOLDING the ‘CLS input’ or
‘CLOSE button’. All other means of closing the door are disabled. Press SET to continue. “
Menu 6.2 PE Beams Input Response Mode
The PE Beams input can be confi gured to respond in one of three modes.
Reverses Close Cycles
In this mode, the PE Beams input has no effect when opening but will cause the door to reverse if activated
when closing.
Close Cycles Stop
In this mode, the PE Beams input has no effect when opening but will stop the door when closing.
Open and Close Cycles Stop
In this mode, all cycles are prevented from being completed or initiated when the PE Beams input is active.
Menu 6.3 PE Beams Obstruction Reverse Time Mode
Normally after a PE Beams obstruction the door will fully open to its open position. After a PE Beam Close
obstruction, the doors open cycle can be reduced from 5 sec to its full open position.
Menu 6.4 PE Beams Type
Axess® Pro Series 3000 shutter opener supports EasyBeam™ or three wire beams.
Menu 6.5 GPI Input
GPI input can be confi gured as OSC, PED or DST setup. The GPI input terminal is activated by the N/O switch.
When GPI Selected As OSC:
Parameter
Min
Max
Default
Step
Unit
Menu No.
OPEN SPEED FREQUENCY
Sets the speed of the motor
15
75
50
1
HZ
5.1
CLOSE SPEED FREQUENCY
Sets the speed of the motor
15
75
50
1
HZ
5.2