background image

1.800.944.4283              AutoGate Technical Support

 

                               

JULY 2016

 

 

 8 

WARNING! 

TO REDUCE THE RISK OF INJURY OR DEATH, READ AND FOLLOW ALL

 

INSTRUCTIONS! 

SAFETY INSTRUCTIONS

 

FOR INSTALLER AND END USER 

Proper design is important in your system layout and installation.  Entrapment devices must be used at all 
available  points  where  injury  or  property  damage  may  occur.  For  protection  from  injury  to  persons,  use     
approved Entrapment devices across the driveway.  Reversing Loops (Vehicle Detectors) should be installed 
in front and behind the gate to provide a reverse signal or stop  signal to the gate operator.  All reversing   
devices should be tested and inspected monthly. If a Reserving Loop or Loop detector malfunction, operator 
should be disabled until repair can be made by an experienced service company.   

In providing the service of “designer” or “installer” of the operator and gate system, you are responsible for 
educating  the 

END  USER 

on  proper  and  safe  operation  of  the  gate  system.    All  precautions  to  eliminate  

hazards 

MUST

 be taken before the system can be put into operation.  All identified entrapment areas are 

required  to be  protected  against  entrapment.   Refer to ASTM  F2200 for  diagrams  of  common  entrapment  
areas.  

 

 

Check the National, State & Local building and fire codes 

BEFORE

 installation 

 

 

If you did not order a 

Reversing  Edge 

(for along the bottom rail of your gate), or an 

Infra-Red  Modulat-

ed  Photocell   

(Reversing Beam), you will 

NOT

 be in compliance with March 2000 UL 325 Code,  Rev 5. 

Consult your dealer for additional information.  

 

 

 

Pedestrians 

must 

use a separate entrance/exit and 

never 

the vehicular entrance/exit gate.

 

 

 

NEVER 

activate  the  gate  from  long  distances  where  visibility  of  the  gate  cannot  be  seen.  Anyone

         

operating the gate should always operate it in a safe manner.  

 

 

 

NEVER 

allow children or anyone to play on or around the gate at any time.

 

 

 

DO NOT 

affix any adhesive material within 30 days of receiving the system.

 

 

 

DO  NOT

  attach  anything  to  the  gate  over  four  (4)  pounds  total  weight  or  four  (4)  square  feet  without   

consulting AutoGate for re-balancing instructions. 

 

The gate must remain balanced to ensure safe and 

reliable operation.  

 

 

The gate and operator are designed to work together. 

DO  NOT

 attempt to install an unauthorized gate 

without AutoGate’s prior authorization and instructions, doing so may VOID the operator warranty.

  

 

 

DO  NOT  ALLOW

 any access control devices to be mounted within 6 feet of the moving gate or in such a 

way that someone could reach their hand or arm through the gate to activate it.

 

 

WARNING! 

THE GATE OPERATOR IS DESIGNED AND FACTORY BALANCED FOR THE SPECIFIC GATE                       

IT WAS SUPPLIED WITH.  

 

DO NOT MODIFY THE GATE IN ANY WAY OR ADD SIGNS WEIGHING MORE THAN 4 LBS TOTAL              

OR FOUR (4’) SQUARE FT.  

 

FAILURE TO COMPLY WITH THIS REQUIREMENT WILL VOID THE WARRANTY AND MAY RESULT                               

IN SERIOUS INJURY OR DEATH. 

Summary of Contents for VPG-24 (LM)

Page 1: ...m Installation Operation Manual Vertical Pivot Gate VPG System VPG Operator 24 LM Before attempting to install operate or maintain the operator you MUST read and fully understand this manual and follo...

Page 2: ...njuries or death can result to someone in the vicinity of a moving gate Some situations that can lead to a possibility of serious injuries or death include absence of separate pedestrian access automa...

Page 3: ...tical pivot gates shall be designed constructed and installed in accordance with security related parameters specific to the application in question 8 Controls intended for user activation must be loc...

Page 4: ...SCUSS THE POTENTIAL FOR A PREVENTATIVE SERVICE AND MAINTENANCE CONTRACT ____ A PHOTO OF COMPLETED INSTALLATION TAKEN FROM FRONT AND BACK OF GATE DATED ____ CUSTOMER TRAINED ON MANUAL OPERATION OF THE...

Page 5: ...mary Secondary Entrapment Protection 7 Recommended Secondary Entrapment Devices 7 Safety Instructions for Installers Owners 8 Orientation 9 11 Preparations Prior to Installation 12 14 Installation 15...

Page 6: ...e supplied with a sepa rate access opening The pedestrian access opening shall be designed to promote pedestrian usage Locate the gate panel drop arm such that persons will not come in contact with th...

Page 7: ...ut is received In order for the gate to close by timer a new input on the terminals J5 1 8 must be given If an input is still present when the gate HAS reached the full open position this input will n...

Page 8: ...ng Edge for along the bottom rail of your gate or an Infra Red Modulat ed Photocell Reversing Beam you will NOT be in compliance with March 2000 UL 325 Code Rev 5 Consult your dealer for additional in...

Page 9: ...tem users from being in the area of the pivoting gate panel drop arm Hand or handing The system comes in left hand or right hand configurations This refers to the location of the operator when viewed...

Page 10: ...a variety of optional electrical components and configuration custom to your specific order Figure 1 1 Operator not depicting Drop Arm or optional gate panel Figure 1 2 Components Housed in the Operat...

Page 11: ...power outage The system can also be configured to operate 1 2 or 3 color traffic lights audible alarm devices external emergency shut off switch output to an external source to indicate gate open clo...

Page 12: ...iscourage the use of the system by anything other than vehicular traffic Determine if there are any accessory components to be installed with your system and necessary conduit used for traffic lights...

Page 13: ...a specific action Proper installation and placement is critical If you purchased Pre formed Loops carefully follow the enclosed installation instructions and use the diagram below for the proper place...

Page 14: ...gate style height and are approximate Operator weighs1150 lbs steel gates are 24 lbs per foot and aluminum gates weigh 19 lbs per foot 1 Have adequate equipment ready to unload your Gate and Operator...

Page 15: ...Operator Arm before lifting for better balance but it is not mandatory If using a Forklift to position Operator only lift from sides only Do not try to lift gate and operator together from the side P...

Page 16: ...1 800 944 4283 AutoGate Technical Support JULY 2016 16 Installing Other Components Cable Wind Bracing Masted Wind Bracing...

Page 17: ...n to restrict pedestrian access in this area Opening Entrapment Zones Gate in OPEN position below shaded area requires installer to install one 1 of the fol lowing Fencing installation of provided gat...

Page 18: ...e batteries 2 Temporarily remove any wires in the main circuit board J5 Strip Terminal 5 rev safety to disable any Reversing devices not installed from preventing the gate from closing 3 With all pers...

Page 19: ...PIN THIS PLUG WILL ONLY FIT INTO A GROUNDING TYPE OUTLET IF THE PLUG DOES NOT FIT IN THE OUTLET CONTACT A QUALIFIED ELECTRICIAN TO INSTALL THE PROPER OUTLET DO NOT CHANGE THE PLUG IN ANY WAY Operator...

Page 20: ...are for the closing timer delay Default is S2 3 ON to provide a eight 8 second delay if activated If S2 7 is on the gate will auto close by timer SWITCH 6 Sets auxiliary Open input terminal 4 at J5 t...

Page 21: ...any input at J5 with control detectors receivers keypads timers etc wires to it must also be run to the same termi nals of the secondary system Along with these control wires both operators MUST share...

Page 22: ...re Installer must fabricate and install loops in the roadway install the control module detector complete the hookup and programs adjust detector sensitivity for good interaction of the loops and the...

Page 23: ...obe Car Sense 101 1 Locate the Car Sense 101 Vehicle Sensing Probe either along the edge of the Exit Drive 2 Once installed run the 2 conductor cable to Socket Base connections 6 7 8 Free Exit Device...

Page 24: ...number 8 is in ON position and if AC power is lost See LED D14 Check LED D12 if lit and AC power is off then batteries need to be charged or replaced Gate Will Not Open Check for AC power loss at D14...

Page 25: ...batteries disconnected set to 27 5 Motor Doesn t Stop If gate closes and motor continues to run the limit switch may need adjustment or replacement IRD Obstruction Signal to Other Gate Note Working Co...

Page 26: ...ard is defective Replace Control Board Check A C Switch Is Switch On Is HBEAT LED flashing or ON Steady Off On Steady Flashing NO YES YES Batteries Low or Bad Check input LED s on top Right Side of Co...

Page 27: ...1 800 944 4283 AutoGate Technical Support JULY 2016 27...

Page 28: ...n between intermediate and final drive sheaves should be tightened to minimum deflection Belt s loose or worn require replacement Every 6 months Charge voltage for batteries should be 27 5 VDC with ba...

Page 29: ...loosen and remove the chain tension bolt with the damaged spring Step 8 Replace damaged spring Step 9 Replace chain tension bolt NOTE Grease fitting must point up Tighten bottom nut NOTE Chain MUST r...

Page 30: ...e up and down cycles should be very close to the same If not you will have to adjust the SLIDE ASSEMBLY Loosen the 1 1 8 nuts on either side of the Slide Assy Angle on the Threaded Rod If the gate Amp...

Page 31: ...1 800 944 4283 AutoGate Technical Support JULY 2016 31...

Page 32: ...1 800 944 4283 AutoGate Technical Support JULY 2016 32...

Page 33: ...1 800 944 4283 AutoGate Technical Support JULY 2016 33...

Page 34: ...1 800 944 4283 AutoGate Technical Support JULY 2016 34...

Page 35: ...1 800 944 4283 AutoGate Technical Support JULY 2016 35...

Page 36: ...1 800 944 4283 AutoGate Technical Support JULY 2016 36...

Page 37: ...1 800 944 4283 AutoGate Technical Support JULY 2016 37...

Page 38: ...1 800 944 4283 AutoGate Technical Support JULY 2016 38...

Page 39: ...1 800 944 4283 AutoGate Technical Support JULY 2016 39...

Page 40: ...1 800 944 4283 AutoGate Technical Support JULY 2016 40...

Page 41: ...1 800 944 4283 AutoGate Technical Support JULY 2016 41...

Page 42: ...1 800 944 4283 AutoGate Technical Support JULY 2016 42...

Reviews: