SAFETY INSTRUCTIONS REGARDING PRIMARY & SECONDARY
ENTRAPMENT PROTECTION
This unit is equipped with one (1) INTERNAL means of entrapment protection. (SEE UL 325 SECTION 30A)
Gate Operator shall provide one (1)
INTERNAL
(INHERENT) AND one (1)
EXTERNAL
entrapment feature.
INTERNAL
:
(TYPE A) – Inherent entrapment sensing systems – operator will reverse direction when the inherent TYPE A
device senses an obstruction.
EXTERNAL:
(TYPE B1) – Provision for connection of a non-contact sensor (Photoelectric or equivalent)
(TYPE B2)— Provision for connection of a contact sensor (Edge devise or equivalent).
NOTE
:
Unit ships with S1-6 ON & S1-8 OFF. DO NOT change these settings (see page 12 for illustration).
PRIMARY PROTECTION
-
TYPE A INHERENT PROTECTION:
The unit will reverse direction when an obstruction is sensed while moving either direction. Sensitivity is
adjusted at the IRD1 on the control board while closing. If an obstruction is sensed by the primary inherent
sensor, the gate will reverse and open to the full open position. The gate will remain open until a close
command is received or will close by timer (if activated) after a new input is received. In order for the gate to
close by timer, a new input on the terminals J5-1-8 must be given. If an input is still present when the gate HAS
reached the full open position, this input will need to be renewed or removed and another input given before
the close timer will close the gate.
ENTRAPMENT ALARM:
Will activate upon the primary inherent sensor sensing a second obstruction before reaching a limit switch.
Once activated, the gate will remain at rest and an alarm will sound. The alarm can only be cleared by an input
applied to J5#4. The wiring used to reset the operator
MUST
be in the line of sight and
MUST
be an
“INTENDED” reset. Access control devices of any kind that require an intended activation may be
used for this reset. Devices that will cause an incidental reset should not be used, these include;
vehicle detectors, probes, timers, motion sensors, photo beams. Turning off the DC battery power
AND
turning off the AC power at the GFCI service outlet will also reset the control board.
WARNING!
FAILURE TO COMPLY WITH THIS REQUIREMENT MAY RESULT
IN SERIOUS INJURY OR DEATH
APPROVED SECONDARY ENTRAPMENT DEVICES
PHOTO BEAMS
1)EMX INDUSTRIES
MODEL#: IRB-325
TRANSMITTER / RECEIVER TYPE
2)ALLEN BRADLEY
MODEL#: 60-2728
RETRO-REFLECTIVE TYPE
3)OMRON / MMTC
MODEL#: E3K-R10K4-NR
RETRO-REFLECTIVE TYPE
REVERSING EDGES (CONTACT EDGES)
MILLER EDGE
MODEL— ME-120
Summary of Contents for VPG-24 (LM)
Page 27: ...1 800 944 4283 AutoGate Technical Support JULY 2016 27...
Page 31: ...1 800 944 4283 AutoGate Technical Support JULY 2016 31...
Page 32: ...1 800 944 4283 AutoGate Technical Support JULY 2016 32...
Page 33: ...1 800 944 4283 AutoGate Technical Support JULY 2016 33...
Page 34: ...1 800 944 4283 AutoGate Technical Support JULY 2016 34...
Page 35: ...1 800 944 4283 AutoGate Technical Support JULY 2016 35...
Page 36: ...1 800 944 4283 AutoGate Technical Support JULY 2016 36...
Page 37: ...1 800 944 4283 AutoGate Technical Support JULY 2016 37...
Page 38: ...1 800 944 4283 AutoGate Technical Support JULY 2016 38...
Page 39: ...1 800 944 4283 AutoGate Technical Support JULY 2016 39...
Page 40: ...1 800 944 4283 AutoGate Technical Support JULY 2016 40...
Page 41: ...1 800 944 4283 AutoGate Technical Support JULY 2016 41...
Page 42: ...1 800 944 4283 AutoGate Technical Support JULY 2016 42...