Assembly Instructions 

 Spindle Drive SP -24 V / 230 V  

9000002601.doc 

Page

 9 

of

 34

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example: light dome 

Activation directly on HSK 
(Mounting on frame or curb)

 

Intended Use 

Area of Application / Range of Application

 

Example: roof area window 

Activation directly on HSK

 

(Mounting on frame)

 

 

Example: fasade area window 

Activation directly on HSK 
(Mounting on bar / waler)  

Area of application

 

For electromotive opening and closing of building openings 
in facades and roof areas. Examples are:bottom-hung, top-
hung, side-hung, vertically pivoting and horizontally pivoting 
casements as well as light domes, flaps and blinds made of 
base materials such as aluminium, plastic or wood. 

For power-operated windows in natural smoke and heat 
exhaust applications (NSHEV) as well as in natural  
ventilation systems. 

The main purpose of this product is to save human lives 
in case of fire. 

The safety features of this product are crucial for compliance 
with the Machinery Directive 2006/42/EC and EN12101-02. 

The most important feature is the 

opening of the window

 

after activation from a control unit (SHEV control unit) or after 
triggering of a fire alarm button or smoke detector or trigger-
ing of the fire alarm unit. 

 

Range of application 

Casement dimensions: 

Casement overall height (FAH)  
Casement overall width  (FAB) 
 
(see individual examples of application) 

Casement weights: 

general fill weight = max. 30kg/m²  

Casement type: 

Roof windows / light domes  / bottom-hung, top-hung,  
side-hung, vertically pivoting and horizontally pivoting  
casements 

Opening direction of casements:

 

outward opening

 

 

 

otherwise dependent on the following components: 

Assembly location / drive stroke / opening width

  

 
Different specifications apply depending on the

 contact 

point

 of the drive. 

The given casement dimensions are only for orientation.  
The actual application range depends on the relationship: 
Outer width of casement (FAB)/(FAH) outer height of case-
ment, total weight of casement and opening width.  
Adherence to drive force path diagrams is essential. 

Please ask for our separate installation documents, 
if required. 

Any use of the drive other than the one specified in 
this document causes loss of warranty.  
The assumption of possible follow-up costs and 
further claims is excluded.

 

 

General Use 

Shown with the following  

example

3

 

Summary of Contents for SP 8 Series

Page 1: ...ler gmbh de www aumueller gmbh de Aum ller Aumatic GmbH Gemeindewald 11 86672 Thierhaupten Germany 49 0 82 71 8185 0 49 0 82 71 8185 250 info aumueller gmbh de www aumueller gmbh de Assembly Instructi...

Page 2: ...ormation are as correct and up to date as possible we still cannot guarantee that they are free from mistakes and errors All information and data contained in this document are subject to alterations...

Page 3: ...e and for specific profile systems 16 Mounting brackets with thick clamping blocks 17 Mounting brackets with thin clamping blocks 18 Mounting brackets with clamping bolt connection 19 Recommended Fixi...

Page 4: ...rning notes in these instructions Failure to comply with the safety instructions warning notes results in irreversible injury or death Failure to comply with the safety instructions warning notes can...

Page 5: ...from the homepage of Aum ller Aumatic GmbH www aumueller gmbh de It is essential to ensure compliance with the latest version of the guidelines standards and national legislation applicable to the as...

Page 6: ...power consumption Required fastening material shall be selected and if necessary completed to suit the drive and the exerted loads Make sure that all products installed are permanently protected from...

Page 7: ...Assembly Instructions Spindle Drive SP 24 V 230 V 9000002601 doc Page 7 of 34 Certificate 2...

Page 8: ...Page 8 of 34 9000002601 doc Assembly Instructions Spindle Drive SP 24 V 230 V Declaration of Incorporation 2...

Page 9: ...after activation from a control unit SHEV control unit or after triggering of a fire alarm button or smoke detector or trigger ing of the fire alarm unit Range of application Casement dimensions Case...

Page 10: ...very many different kinds of window profile systems on the market Different mounting brackets and fastening devices to be used depend on the particular profile On the pages below you may find special...

Page 11: ...Tilting range Supporting surface of bracket Supporting surface of bracket Structural factors obstacles e g jamb WARNING Storage of the drives on site prior to the assembly Protective measures against...

Page 12: ...product features Silver anodized aluminium body E6 C 0 Robust aluminum spindle Maintenance free drive RAL colour finish possible Versions has disconnection via end switches and disconnection at overlo...

Page 13: ...al description product features Silver anodized aluminium body E6 C 0 Robust aluminum spindle Maintenance free drive RAL colour finish possible Versions and Standard has internal disconnection via end...

Page 14: ...extended spindle if unit suspended at rear Front suspension Rear suspension L L ength KLB Clamping area 2 3 KLB 1 3 KLB optional eye bolt for fixing Fixing with clamping bolt connection Observe speci...

Page 15: ...ive to be used must be selected to suit the specified range of application appropriate stroke stroke force and installation length 3 Proper fastening accessories brackets casement brackets must be sel...

Page 16: ...F 1 casement bracket with locking bolt 6 mm Max load 1000 N ord no 150102 F 2 casement bracket extruded aluminium for Eternit roof lights Max load 800 N ord no 150303 FXXX 8 F 11 casement bracket wit...

Page 17: ...r clamping fitting with 2x 12 mm collar screws ord no 157500 6 5 x4 K 5 mounting bracket stainless steel V2A with 12 5 mm hole for clamping fitting with 2x 12 mm collar screws ord no 155800 12 14 G 1...

Page 18: ...155610 6 5 x6 K 82 mounting bracket stainless steel V2A with 12 5 mm hole for clamping fitting with 2x 12 mm collar screws ord no 151320 7 20 36 G1 8 KS clamping block SP thin aluminum for mounting br...

Page 19: ...ting bracket with 20 mm hole steel br zinc plated ord no 160930 steel RAL 9010 ord no 160933 6 5 x4 100 30 70 20 6 5 x4 5 K 9 mounting bracket aluminium E6 C 0 for mounting with various brackets ord n...

Page 20: ...crews Metric screws with blind rivet nuts Thread self tapping or sheet metal screws such as Cylinder head with hex socket internal serration Torx Phillips or external hex head Blind rivet nut size M6...

Page 21: ...e correct torque Fixation of brackets in guide of sliding link with clamping screws K5 2x KS thick 2 x BS K7 2x KS thin K82 2 x BS KVS K57 K57 2 K57 3 K59 K92 1 2 3 4 2 x KVS Fixation of brackets in g...

Page 22: ...openings Adjustment possibility for disconnection loosen lock nut manually turn AS inward and or outward dependent on assembly tighten lock nut again ensure that drive shuts off via end switch and no...

Page 23: ...0 1400 1600 1800 2000 2200 2400 2600 Abstand Antrieb Band mm ffnungswinkel DEG 1 Hubl nge 100mm 2 Hubl nge 200mm 3 Hubl nge 300mm 4 Hubl nge 400mm 5 Hubl nge 500mm 6 Hubl nge 600mm 7 Hubl nge 700mm 8...

Page 24: ...w e g top hung projecting casement RA K82 M6 base plate set on site F10 6 FL M6 F1 RA FL Roof casement system SCH CO AWS 57RO outward opening on HSK K82 F10 6 Roof casement system FAKRO outward openin...

Page 25: ...C T IT E 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 FG 16 Fit the casement bracket make sure it is parallel to the edge of...

Page 26: ...f the window e g borehole intervals determined on site Dimensions for brackets see page 17 19 Hang drive in mounting brackets e K59 g for installation of bracket positioning fixing see page 21 22 Do n...

Page 27: ...ut off via end switch see page 22 Route cable according to on site situation the cable must adapt to pivoting angle of the drive lay with strap Cable must be protected against damage such as shearing...

Page 28: ...Check safety of assembled system Connect control voltage Check fasteners brackets mounting brackets and tighten as necessary Perform operational test Visual inspection of casement movements Immediatel...

Page 29: ...DC BN BU Version with Z contact close 2 1 BK WH CLOSE 3 4 3 4 BK WH Switch position with spindle inside Contact load max 48V min 12V DC 10mA PVC cable 6 x 0 75mm with electronic end switches and overl...

Page 30: ...drive cable A mm L A mm Example calculation Available figures 10m Drive current for each drive 2 x 0 8 A from data sheet Length of cable run from last window to control unit e g The number of wires r...

Page 31: ...switch with OFF default setting min 1 5m Mount all manual controllers out of reach for unauthorized persons Instructions OPEN CLOSE Sign such as spindle chain rack and pinion Drive Target group This o...

Page 32: ...motor controller relay Cables Copper Zinc Electrical devices and batteries cannot be disposed of as domestic waste Locking fittings Drive such as spindle chain rack and pinion Problem Possible Causes...

Page 33: ...ertifica tion authorities energy supply companies or fire protection au thorities if necessary Extra low voltage lines e g 24 V DC must be laid separately from low voltage lines e g 230 V AC Flexible...

Page 34: ...causes Improper use of the drive Improper assembly commissioning operation maintenance and repair of the drive Operating the drive with defective improperly installed or malfunctioning safety and pro...

Page 35: ...Assembly Instructions Spindle Drive SP 24 V 230 V 9000002601 doc Page 35 of 34 Notes...

Page 36: ...Engineering Service Systemtechnik Rauch und W rmeabzug Parkraum Management Kontrollierte nat rliche L ftung...

Reviews: