Assembly Instructions
•
Spindle Drive SP -24 V / 230 V
9000002601.doc
Page
29
of
34
Electrical connections
19
OPEN
CLOSE
Direction of travel
Reverse polarity
+
+
-
-
24 V DC
230 V AC
Attention! Danger of electric shock!
- Drive is not suitable for
switch-over of the running direction !
Make sure that no 230 V line voltage is live on terminals during the drive connection !
- Note: Switch off the operation voltage after ca. 3 min. in order to save energy (accord. to regulations of Euro ACE)
direct
+
+
-
-
BU
BN
Silicone cable
2 x 0,75mm²
(with electronic end switches and
overload disconnection)
SP 8
Drive type
24 V DC
BN
BU
Version:
without Z (close) contact
2
1
+
+
-
-
BU
BN
Silicone cable
4 x 0,75mm²
(with electronic end switches and
overload disconnection and additional
floating contact for closed position)
SP 8- Z
Drive type
24 V DC
BN
BU
Version: with Z
contact
(close)
2
1
BK
WH
CLOSE
3
4
3
4
BK
WH
Switch position with
spindle inside
Contact load:
max. 48V
min. 12V DC, 10mA
PVC cable
6 x 0,75mm²
(with electronic end switches and
overload disconnection and additional
floating contact for closed position)
SP 8-Z
Drive type
Version: with Z (close) contact
BN
BU
Connection diagram
2
1
BK
WH
5
CLOSE
4
5
GY
WH
Switch position with
spindle inside
Contact load:
max. 230V AC, 2A
min. 12V DC, 10mA
GN/YE
Colour
IEC 757
BLACK BK
WHITE WH
BROWN BN
BLUE BU
GREEN / YELLOW GN/YE
GREY GY
according
to
Wire colour coding
4
GY
3
6
M
BU
BK
BN
GN/
Y
E
230 V, 50 Hz
PE N
L
1 2 3
CLOSED
OPEN
0
open close
BK
BN
L
Note:
Unused wires must be
safely terminated – risk of short-circuit!
- Please pay regard to the general
safety instructions on page 6 and
page 33 (cable routing).
Carry out the electrical connection according to the drive variant
.
Note:
The direction of travel of the drive may be changed by interchanging (polarity reversal) the wires
„
BN – (brown)
“ - „
BU – (blue)
“
.