33
RWA Control Unit
LSF 7000
i
nStaLLation
S
tep
1:
C
onneCtion
of
the
D
rives
anD
v
entilation
b
uttons
Connection of the drives and ventilation buttons:
Control Unit version
LSF 7000-10A-0102
and
LSF 7000-20A-0102
Connection of the drives and ventilation buttons:
Control Unit version
LSF 7000-5A-0101
and
LSF 7000-10A-0101
BU
1
2
3
BN
M
Leitungs-
Endmodul
1
1
1
22
5
71
A
S
B
A
Z
A
Z
1 2 3
1 72
1 32 33 35 36 37
1 13 14 15 16 17
18 19
1 32 33 35 36 37
ca. 1 s
=
=
-
+
+
-
1 2
Klemme
B
K
BN
BU
B
K
O
G
USB
M
1
2
3
4
5
6
2 3 4 5 6
1
!
!
BUS
Drive
24 V DC
Drive
24 V DC
Insert line end module
at the last drive
of the line!
LSF 7000 -
5 a
= max. 5 A (Rated current)
LSF 7000 -
10 a
= max. 10 A (Rated current)
Plug-in terminals!
Remove for connection!
max.
400 m
max.
10 pieces
OPEN
CLOSE
OPEN
CLOSE
open
close
ventilation
RM
HSE
Plug for
fr
ont button
5 a
20 a
10 a
10 a
BU
1
2
3
BN
M
BU
1
2
3
BN
M
Leitungs-
Endmodul
Leitungs-
Endmodul
1
1
1
22
5
71
A
S
B
A
Z
A
Z
1 2 3
1 72
1 32 33 35 36 37
1 13 14 15 16 17
18 19
1 32 33 35 36 37
A
Z
A
Z
1 32 33 35 36 37
1 32 33 35 36 37
1 2 3
=
=
-
+
+
-
1 2
Klemme
B
K
BN
BU
B
K
O
G
ca. 1 s
USB
M
=
=
-
+
+
-
1 2
Klemme
B
K
BN
BU
B
K
O
G
M
1
2
3
4
5
6
32 33 35 36 37
1
!
!
BUS
Drive
24 V DC
Drive
24 V DC
Insert line end module
at the last drive
of the line!
Plug-in terminals!
Remove for connection!
max.
400 m
max.
10 pieces
OPEN
CLOSE
OPEN
CLOSE
open
terminal
open
close
close
RM
HSE
Plug for
fr
ont button
Ventilation button /
Ventilation switch
Ventilation button /
Ventilation switch
!
!
Drive 1
Drive 2
ventilation 2
ventilation 1
LSF 7000 -
5 a
= max. 5 A (Rated current)
LSF 7000 -
10 a
= max. 10 A (Rated current)
LSF 7000 -
20 a
=
2
x
max.
10 a
(Rated current)
Drive 1
Drive 2
connection
like ventilation 2
ventilation 1
ventilation 2
In event of fire, RWA activation has
priority over ventilation operation.
No ventilation operation if mains power
supply fails (battery operation).
In event of power failure/malfunction,
smoke exhaustion system is opened.
In event of fire, RWA activation has
priority over ventilation operation.
No ventilation operation if mains power
supply fails (battery operation).
In event of power failure/malfunction,
smoke exhaustion system is opened.
Drive
Option:
Self-retaining
Standard:
dead man’s mode
Option:
Self-retaining
Standard:
dead man’s mode
line end
module
05
Terminal
Terminal