20
Assembly Instruction
KSA - T
WIN
S12 24V DC
I
NSTALLATION
STEP
9
B
:
A
SSEMBLY
FRAME
BRACKET
- D
RIVE
MOUNTED
ON
THE
WINDOW
AT
THE
B
UTTON
05
¢
Produce drill holes with appropriate cross-section.
For the mounting dimensions please refer to the
above-mentioned hole layout drawings (see chapter
„I
NSTALLATIONSTEP
5 - 7“) or pro
ject-specifi c documents
and drawings).
¢
Fit frame brackets (Kxxx).
Make sure they are parallel to casement edge.
¢
Route cable on the frame or mullion/transom.
The drive and its connection cable are swivelling. As a
consequence, foresee cable routing with a loop. Cable
must be protected against damage (shearing-off,
kinking, splitting).
¢
Attach drive to the frame brackets.
¢
Insert brass washers
•
and fi rmly tighten with
countersunk screws M8
Œ
. Drive should freely swivel.
Check swiveling area (see chapter „S
AFETY
C
HECK
AND
P
ERFORMING
TEST
RUN
“).
Ensure that drive and connection cable can
swivel freely.
!
!
transom
transom
cable duct glued on
(in addition secured with countersunk screws against
breaking away)
Kxxx
Kxxx
FL
FL
RA
RA
2 x M5
parallel
Kxxx
transom
Fxxx
FL
I
NSTALLATION
STEP
9
B
:
A
SSEMBLY
FRAME
BRACKET
- D
RIVE
MOUNTED
ON
THE
WINDOW
AT
THE
B
UTTON
¢
Insert the Chain unlocking key
y
in the hole.
¢
Pull both chains out maually by the same distance (see
chapter: „A
DJUSTING
THE
INITIAL
CHAIN
TENSION
AND
SMOOTH
RUNNING
“.
¢
Connect chain with casement bracket. Pass shaft screw
M6 through and tighten.
1
2
RA
A
5