17
The central locking control unit receives this
signal simultaneously and unlocks the vehicle
doors. The hazard warning lights are activated
automatically and the interior lighting is swit-
ched on.
A restart function enables the engine to be
restarted after an accident and it can be
moved from the danger zone under its own
power.
The fuel tank is made of plastic and is housed
in a protected position in front of the rear axle.
Airbag
control unit
Motronic
control unit
Fuel relay
Door locking
unit
Hazard
warning
switch
Interior
lighting
Central locking control
unit and anti-theft
warning system
Fuel pump
Fuel cut-off
J234
J220
J17
J379
F220...223
E3
G6
The Audi TT Coupé is the first Audi to
be equipped with a fuel cut-off.
In connection with an airbag trigger
mechanism (crash signal output), the
Motronic control unit switches the fuel
pump off.