Table 3. Parameters in System Config menu.
Name
Description
Range
Initial Note
Program Mode
Multi-Step Program
ON, OFF
ON
12
Output Hi Limit
Output High Limit %
0 - 100
100
13
Temp Unit
Temp Unit (°C or °F)
C, F
F
14
Smkr Probe Offset
Cabinet Probe (Probe 1) Offset
-9 - 99
0
15
Fd Probe Offset
Food Internal Probe (Probe 2) Offset
-9 - 99
0
15
Probe3 Offset
Probe 3 Offset
-9 - 99
0
15
Probe3 Enabled
Probe 3 Readout Option
Yes, No
Yes
16
Step End Alarm
Step Ending Alarm
ON, OFF
ON
17
Backlight Level
LCD Backlight Level
0 - 10
10
18
Dwell Time
Data Logging Sampling Interval (App) 1min - 5min
1min
19
nFlt
Power Line Digital Filter
Auto, A, B
Auto
22
Password
Device Access Password (App)
100 - 999
777
20
Factory Reset
Factory Reset
Yes, No
No
21
Back
Back to Upper Level Menu
00000000000000000000
00000000000000000000
> System Con f i g
Back
00000000000000000000
00000000000000000000
>Program Mode ON
Output Hi L im i t 100
00000000000000000000
00000000000000000000
Program Mode ON
Program Mode OFF
Output H i L im i t 100
Output H i L im i t 95
SE T
SE T
SE T
/
/
SE T
SE T
00000000000000000000
00000000000000000000
>Back
Program Mode ON
SET
>Output H i L im i t 100
Temp Unit F
Figure 27. Access the parameters in System Config menu.
Note 12. Program Mode:
Multi-step program switch. By default, this controller is set to
multi-step mode, and this parameter is set to “ON”. If you want to change it to single-step
mode, please change this parameter to “OFF”. For details regarding multi-step mode,
please check section 4.1.3
Note 13. Output Hi Limit:
It is expressed as a percentage value. This function will allow
you to control the maximum output power delivered by the heater. For example, if you
set
Output Hi Limit
= 50 and your heater is 1000 watts, the output will use 50% of the
1000 watts as the full output. It thinks the 1000W heater as a 500W heater. When the