25/31
Note 18. Backlight Level:
LCD backlight level setting. The higher the value, the brighter
the LCD display. 0 is lowest brightness. 10 is highest brightness.
Note 19. Dwell Time:
Data Logging Sampling Interval. This parameter controls the
temperature sampling interval, which will be used for data export function and plot display
on Aubersmart app. The controller will store 5 data traces in total: SV, Probe 1 reading
(cabinet), Probe 2 reading (food probe), Probe 3 reading and the output power
percentage. Each trace can store up to 300 data points. The temperature plot of the
Aubersmart App has two scales. One can display the latest 300 data points and other can
display the latest 120 data points. The default setting of Dwell time is 1 minute per sample.
At this setting, 300 minutes (or 5 hours) of data points can be stored. User can display
the plot in either 5 hours or 2 hours. The dwell time can be set in the range of 1 minute to
5 minutes. Table 4 shows the available plot scales for the corresponding dwell time.
Table 4. Available options for Dwell Time.
Dwell Time Option
(Interval time per sample)
Maximum Logging Time
Plot Display Option
1-minute
5-hour
2-hour/5-hour
2-minute
10-hour
4-hour/10-hour
3-minute
15-hour
6-hour/15-hour
4-minute
20-hour
8-hour/20-hour
5-minute
25-hour
10-hour/25-hour
Note: Once the dwell time is set, the app can only display the temperature plot in the two
scales listed in the table. If you want to change the dwell time in the middle of cooking,
you will lose all the data logged before the change. If you want keep the data, you should
export the data before change this setting.
Note 20. Password:
Device access password. This parameter is used to lock the access
to parameter settings on Aubersmart app. Default password is 777.
Note 21. Factory Reset:
Factory reset. This function will restore all the parameters
(including all the stored recipe settings in the memory) back to the factory default values.
This setting will not reset the WiFi configuration. To reset the WiFi setting on the controller,
please press and hold SET key and TIME key for 5s, until the blue WiFi indicator starts
to blink.
Note 22. nFlt:
Power line digital filter. This filter is for rejecting the power line interference.
There are three settings: “Auto” for auto-detect mode (default), “A” for 50 Hertz
interferences and “B” for 60 Hertz interferences. If you encounter fast fluctuating
temperature reading issue, you can change this setting to “A” or “B” manually, based on