Specifications
Number of storable recipes
6
Number of steps in each recipe
6
Input voltage
US 120V, European 220V, 50/60 Hz
Output voltage
The same as the input.
Maximum Current
15A for 120V AC, 12A for 220V AC, 3A for the smoke
generator output.
Controller Mode
PID, PI, PD or P.
Output switching device
Built-in optically isolated solid state relay with zero voltage
crossing switching.
Sensor type
PT1000 RTD sensor
Timer range
6 steps with 23h59m for each step.
Temperature resolution
1°C or 1°F.
Temperature display unit
Celsius or Fahrenheit.
Temperature display range
-40 - 400°C, or -40 - 750°F.
Mini. Control Temperature
5°C (9°F) above ambient with smoker generator off, 22
°C (40°F) above ambient with smoker generator on.
Max. Control Temperature
300°C (570°F), limited by sensor cable.
Temperature accuracy
+/-1°C
Smoker generator control output maximum current
3A at 120V
Dimension
6 x 3 x 8.3 inch (155 x 80 x 210 mm) W x H x D.
Weight
3.2 lb (1.4 kg).
Warranty
One (1) year for the controller, 90 days for sensors.
Note: This controller has US input plug and output socket that meet the NEMA 5-15
standard. For international order, user can get a converter from local electronics store to
convert the connection. For countries that use 220-240VAC power line, the maximum