Smkr Lo Alarm
, you can set it to a small number, such as 0°F (default).
00000000000000000000
00000000000000000000
Smkr Low A l arm
Press
v
to Cance l
Figure 23. The LCD display when
Smkr Lo Alarm
is triggered.
Note 3. Food Hi Alarm:
This is the high temperature alarm for the food internal probe
(Probe 2). When food probe reading is higher than
Food Hi Alarm
, the buzzer on the
controller will go off and the LCD display will flash between the normal display and the
alarm display showing in Figure 24. The alarm has 1 degree hysteresis. The user can
mute the buzzer by pressing either the Up key or the Down key. For example, if
Food Hi
Alarm
is set to 130°F, the buzzer will go off when Probe 2 reads 131°F, and the buzzer
will stop when Probe 2 reads 129°F or lower. To disable
Food Hi Alarm
, you can set it
to a large number, such as 650°F.
When smoking multiple pieces of meat of different sizes or thickness, you can put the
probe in the thinnest piece first. Set the
Food Hi Alarm
to the temperature when meat
is ready. It will let you know when it is done. Then, you can move the probe to the second
thinnest pieces and so on. To use this feature, you can set the ending criterion to time. If
you prefer to set the ending criterion to food temperature, then the Food Temp
should be
set to higher than
Food Hi Alarm
.
00000000000000000000
00000000000000000000
Food H i gh A l arm
Press
v
to Cance l
Figure 24. The LCD display when
Food Hi Alarm
is triggered.
Note 4. Probe3 Hi Alarm:
This is the high temperature alarm for probe 3. When food
probe 3 reading is higher than
Probe3 Hi Alarm
, the buzzer on the controller will go off
and the LCD display will flash between the normal display and the alarm display showing
in Figure 25. The alarm has 1 degree hysteresis. The user can mute the buzzer by
pressing either the Up key or the Down key. For example, if
Probe3 Hi Alarm
is set to
130°F, the buzzer will go off when Probe 3 reads 131°F, and the buzzer will stop when
Probe 3 reads 129°F or lower. To disable
Probe3 Hi Alarm
, you can set it to a large
number, such as 650°F.
00000000000000000000
00000000000000000000
Probe3 H i gh A l arm
Press
v
to Cance l
Figure 25. The LCD display when
Probe3 Hi Alarm
is triggered.