> Cont ro l Sett i ng
System Con f i g
00000000000000000000
00000000000000000000
>Smkr Hi A l arm 350
Smkr Lo A l arm 50
00000000000000000000
00000000000000000000
> Smkr Hi A l arm 50
Food Hi A l arm 350
Smkr Hi A l arm 350
Smkr Hi A l arm 250
Smkr Hi A l arm 50
Smkr Hi A l arm 50
SE T
SE T
SE T
/
/
SE T
SE T
00000000000000000000
00000000000000000000
>Back
Smkr Hi A l arm 350
SET
Figure 21. Access the parameters in Control Config menu.
Note 1.
Smkr Hi Alarm
: This is the high temperature alarm for cabinet temperature
(Probe 1). When cabinet probe reading is higher than
Smkr Hi Alarm
, the buzzer on the
controller will go off and the LCD display will flash between the normal display and the
alarm display showing in Figure 22. The alarm has 1 degree hysteresis. The user can
mute the buzzer by pressing either the Up key or the Down key. Temperature must move
out of the hysteresis zone to activate the alarm again. For example, if
Smkr Hi Alarm
is
set to 290°F, the buzzer will go off when Probe 1 reads higher than 291°F, and the buzzer
will stop when Probe 1 reads lower than 289°F. To disable
Smkr Hi Alarm
alarm, you
can set it to a large number, such as 750°F.
00000000000000000000
00000000000000000000
Smkr H i gh A l arm
Press
v
to Cance l
Figure 22. The LCD display when
Smkr Hi Alarm
is triggered.
Note 2. Smkr Lo Alarm:
This is the low temperature alarm for cabinet temperature
probe (Probe 1). When cabinet probe reading is lower than
Smkr Lo Alarm
, the
buzzer on the controller will go off and the LCD display will flash between the normal
display and the alarm display showing in Figure 23. The alarm has 1 degree hysteresis.
The user can mute the buzzer by pressing either the Up key or the Down key.
Temperature must move out of the hysteresis zone to activate the alarm again. For
example, if
Smkr Lo Alarm
is set to 180°F. The buzzer will go off when cabinet
temperature drops to 179°F; it will stop when temperature rise above 181°F. The
Smkr
Lo Alarm
is suppressed when the controller is just powered up. It will be activated
when the cabinet temperature has reached the target cabinet temperature. To disable