Operating Instructions 

1.  Description of the controller 

 

1

2

3

4

5

6

8

7

 

Figure 1. Front Panel. 

 

1) 

LCD display window

 – During normal display mode, it will display temperature 

readings from all probes and set temperature for cabinet. When high or low limit 
alarm is triggered, this display will show alarm notification. In time checking mode, 
it will display time/step information. In cooking profile or parameter setting modes, 
it will display the step/parameter name and its value. For details, please check 
section 3.   

2) 

Alarm status/smoke generator indicator (Red)

– This indicator has two 

functions. When this indicator is blinking, temperature alarm is triggered. The LCD 
display will flash the alarm notification at same time. When this indicator is solid 
ON, the smoke generator control output is activated.   

3) 

Output status indicator (Green)

- This LED indicates the output status that 

should be synchronized with heater. When this indicator is ON, the heater is 
powered. When it is OFF, the heater’s power is off. When it is flashing, it means 
the heater is on and off intermittently to reduce the power output. It is 
synchronized with the power light on the cooking device. 

4) 

Wi-Fi status indicator 

(

Blue

) – It indicates the Wi-Fi connection status of the 

controller. Solid ON: the controller is connected to the internet. Fast flashing: Wi-Fi 

Summary of Contents for WSD-1500H-W

Page 1: ...his plug and play controller is very easy to operate the process involves high temperature and high wattage appliances and your safety is paramount SAFETY WARNINGS This controller is designed only to...

Page 2: ...hing device Built in optically isolated solid state relay with zero voltage crossing switching Sensor type PT1000 RTD sensor Timer range 6 steps with 23h59m for each step Temperature resolution 1 C or...

Page 3: ...his indicator has two functions When this indicator is blinking temperature alarm is triggered The LCD display will flash the alarm notification at same time When this indicator is solid ON the smoke...

Page 4: ...up the menu or mute the buzzer Figure 2 Back Panel Up to three temperature probes can be used with this controller and they need to be plugged in P1 P2 and P3 sockets on the right of the back panel P1...

Page 5: ...to the meat Figure 3 Sensor position Left the sensor should be placed close to the food but high enough so that it does not touch the food Right hold the sensor in place by a piece of tape For the Ori...

Page 6: ...power cord that came with the Bradley Smoker for connecting the smoker generator to the power outlet b Connecting the controller to the smoker generator You should use the power cord that originally...

Page 7: ...to the Bradley Smoker Tower with the power cord that came with the Auber Controller Auber Controller Smoke Generator Smoker Tower Probe 1 Cabinet Temp Probe 2 Internal Temp Cable A Cable B To Power Ou...

Page 8: ...moker generator should be connected directly to the wall outlet Connect the controller output with the smoker tower Auber Controller Smoke Generator Smoker Tower Probe 1 Cabinet Temp Probe 2 Internal...

Page 9: ...mentarily SET Time Checking SET Press Momentarily Parameter Settings Figure 9 Switching between different display modes Four display modes are available 1 Normal display 2 Time Checking 3 Cooking Prof...

Page 10: ...s ended by time multi step mode Display 1 if current step is ended by time In normal mode press timer key momentarily to display the elapsed time for current step top and remaining time for current st...

Page 11: ...Set 250 Probe3 270 SET Press Momentarily 00000000000000000000 00000000000000000000 Step 1 SmkrTemp 250 1 Ending by Fd Temp 00000000000000000000 00000000000000000000 1 Fd Temp 195 Step 2 SmkrTemp 200...

Page 12: ...time period set X Ending by Time if you want Step X to be ended when food internal temperature reaches a pre set value set X Ending to Fd Temp After you set X Ending to Time you will need to set X Ti...

Page 13: ...en food internal temperature reaches 160 F the controller will shut off the heater and stop the program it will give beeping sound until the buzzer is muted or the power input has been reset A flow ch...

Page 14: ...000000 2 Ending by Fd Temp 2 Fd Temp 195 00000000000000000000 00000000000000000000 2 Fd Temp 195 Step 3 SmkrTemp 250 Step 2 SmkrTemp 250 Step 2 SmkrTemp 190 2 Ending by Fd Temp 2 Ending by Fd Temp 2 F...

Page 15: ...ware version 1 7 4 or newer User can check or change current program running status by this parameter It can be used to stop start the program or jump to a different step This parameter is under the C...

Page 16: ...g menu find parameter Program Mode then change it to ON for multi step mode or OFF for single step mode By default the controller is set to multi step mode ON Please see the flow chart in Figure 20 fo...

Page 17: ...al Note Smkr Hi Alarm Cabinet Probe High Alarm Probe 1 0 750 350 1 Smkr Lo Alarm Cabinet Probe Low Alarm Probe 1 0 750 50 2 Food Hi Alarm Food Probe High Alarm Probe 2 0 650 350 3 Probe3 Hi Alarm Prob...

Page 18: ...set to 290 F the buzzer will go off when Probe 1 reads higher than 291 F and the buzzer will stop when Probe 1 reads lower than 289 F To disable Smkr Hi Alarm alarm you can set it to a large number su...

Page 19: ...e when meat is ready It will let you know when it is done Then you can move the probe to the second thinnest pieces and so on To use this feature you can set the ending criterion to time If you prefer...

Page 20: ...ree This parameter controls the output of the controller based on the difference between the measured and set temperature Larger the P number means the weaker the action lower gain If P 7 the proporti...

Page 21: ...he temperature drops too much Note 9 T Control Cycle Time The unit is second This unit determines how long for the controller to calculate each action e g If T is set to 10 seconds when controller dec...

Page 22: ...SET SET 00000000000000000000 00000000000000000000 Back Smkr Hi Alarm 350 SET Figure 26 Flow chart of saving a recipe Note 11 2 Recall a recipe You can recall your previous saved recipe to your current...

Page 23: ...em Config Back 00000000000000000000 00000000000000000000 Program Mode ON Output Hi Limit 100 00000000000000000000 00000000000000000000 Program Mode ON Program Mode OFF Output Hi Limit 100 Output Hi Li...

Page 24: ...oker contains more than 38 Liter 10 Gallon of water It might take more than 90 minutes of full power heating for controller to heat up the pot Long time of full power operation might cause the control...

Page 25: ...y Option 1 minute 5 hour 2 hour 5 hour 2 minute 10 hour 4 hour 10 hour 3 minute 15 hour 6 hour 15 hour 4 minute 20 hour 8 hour 20 hour 5 minute 25 hour 10 hour 25 hour Note Once the dwell time is set...

Page 26: ...urs by the heater of the generator without using the heater in the smoker c Damper position Keeping the damper open will result in better temperature stability because more heat loss is created This i...

Page 27: ...stantaneously and when it s turned off it stops heating instantaneously In contrast a hot plate may take several minutes to begin heating when electricity is applied and even longer to start cooling w...

Page 28: ...ogress When the display stops flashing the auto tuning is finished Now the newly calculated PID parameters are set and are used for the system The new parameters will store in the memory even the powe...

Page 29: ...All rights reserved No part of this manual shall be copied reproduced or transmitted in any way without the prior written consent of Auber Instruments Auber Instruments retains the exclusive rights to...

Page 30: ...duct or any of its parts which have been performed by a repairperson or facility not authorized by Auber Instruments This warranty is available to the original purchaser of the unit and excludes all o...

Page 31: ...ssing through the controller 20 watt of heat is produced in the controller As more heat is produced the temperature inside the controller will rise If it reaches to higher than 70 C it can shorten the...

Page 32: ...issue 2 Limit maximum output power If you set output reduction parameter to 80 then a 18A heater will become a 14 4 A heater It will take 25 longer time to heat up the pot but the controller will not...