17/31
7.1 Control Configurations
Parameters related control configurations during the smoking process are listed under
“
Control Config
” menu.
Error! Reference source not found.
shows the list of
these
parameters, their range and initial set value when left the factory.
The flow chart in
Figure 21 shows the operations of accessing and adjusting the parameters in “
Control
Config
”.
Table 2. Parameters in Control Config menu.
Name
Description
Range
Initial Note
Smkr Hi Alarm
Cabinet Probe High Alarm
(Probe 1)
0 - 750
350
1
Smkr Lo Alarm
Cabinet Probe Low Alarm
(Probe 1)
0 - 750
50
2
Food Hi Alarm
Food Probe High Alarm
(Probe 2)
0 - 650
350
3
Probe3 Hi Alarm
Probe 3 High Alarm
0 - 650
300
4
Relay Action
Smoke Generator
Relay Setting
0 - 63
0
5
P (Proportional)
Proportional Constant
1 - 999
7
6
I (Integral)
Integral Time
0 - 9999
600
7
D (Derivative)
Derivative Time
0 - 999
150
8
T (Cycle Time)
Control Cycle Time
2 - 200
2
9
Auto-tune
Auto-tune
ON, OFF
OFF
10
Save Recipe
Save Recipe Settings
Back, B1, B2, C1, C2, F1, F2
Back
11
Recall Recipe
Recall Recipe Settings
Back, B1, B2, C1, C2, F1, F2
Back
11
Back
Back to Upper Level Menu