background image

Version 1.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

VERSION 1.2

 

INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS

 

RIFT® 400 Sub

-

Sea Actuator 

 

Summary of Contents for RIFT 400

Page 1: ...Version 1 2 1 VERSION 1 2 INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS RIFT 400 Sub Sea Actuator...

Page 2: ...OLENOID 7 CONFIGURING AS A MULTI TURN ACTUATOR 8 CONFIGURING AS A MULTI TURN ACTUATOR CONTINUED 8 CONFIGURATION AND CONNECTION WITH ANDROID 8 PAIRING RIFT WITH ANDROID 8 RUNNING THE ANDROID APP 8 UPDA...

Page 3: ...ON FAILURE TO OPERATE 18 OVER TORQUE INDICATION 18 3 WAY BALL VALVES DEFAULT FLOW PATTERNS 19 3 WAY BALL VALVES DEFAULT FLOW PATTERNS CONTINUED 19 BLUETOOTH 19 BATTERY FAILSAFE FUNCTION BFS 20 METHOD...

Page 4: ...correct operation and that non adherence to the warnings WILL result in product failure and potential personal injury and or consequential damage STORAGE Store in a well ventilated and dry room Actuat...

Page 5: ...at the bolts do not reach the solid bottom of the threaded fixing before the bolt is tight against the valve flange Ensure that the valve is in the same position as the actuator when assembling the va...

Page 6: ...n as the angle for the Closed position and adjust it as so PROCEDURE TO USE CALIBRATION MODE TO MOUNT TO A ISO 5211 FLANGE MOUNT a Move the actuator to the closed position b Mount the RIFT 400 actuato...

Page 7: ...nt to solenoids the RIFT 400 introduces end of travel confirmation local controls and torque protection and as an extra cost option speed control Note Thermostatic Anti condensation Heaters These are...

Page 8: ...0317 1177 select the Actuator you wish to pair with Enter the default pairing code 1234 the actuator should be displayed under the Paired Devices list RUNNING THE ANDROID APP Open the App this will ta...

Page 9: ...ware Version Displays the version of the firmware flashed onto the RIFT 400 App Version Displays the version of the App you are running Valve Orientation Set the valve orientation of the valve stem 45...

Page 10: ...ted to Torque Limit Back off allows the user to specify the angle that the actuator will back off if the Torque Limit is reached The RIFT 400 Actuator will display an Orange on the top indicating that...

Page 11: ...l feed back the actual RIFT 400 Actuator position in either 0 10v or 0 4 20mA respective to the control signal input Volt free switch connection is connected through pin 1 0 10v and pin 2 0 10v on the...

Page 12: ...are not easily assessable We advise additional external battery storage is available to prolong operations on a predetermined cycle WIGGLE This function will allow the RIFT 400 Actuator to be programm...

Page 13: ...s on Pins 1 4 See page 15for wiring diagram Follow the wiring diagram appropriate to your functional requirement to ensure the correct connection of power and control signaling to the RIFT 400 actuato...

Page 14: ...0 pin connector supplied is used via the left entry and the right entry connected with 5 core cable onto the 5 pin connection block fitted for the command signals If the end of travel confirmation rel...

Page 15: ...FT 400 actuator either or make minor setting adjustments Soft reset of the electronics similar to the Ctrl Alt Del under Basic Settings option on the Android App only Reset Board Without Changing Sett...

Page 16: ...is awake Displaying in the open position Displaying in the closed position The RIFT 400 is now ready to either start functioning as an ON OFF reversible electric actuator It is helpful in an emergency...

Page 17: ...returning the actuator to normal remote control selected position If it is essential that the actuator moves to a pre determined position upon external power failure you must select and configure the...

Page 18: ...t the actuator but also the valve is fitted onto within its operational torque bands If the maximum torque is exceeded through either blockage or trying to exceed the operational design the LED s on t...

Page 19: ...where applicable by selecting using the relevant buttons on the screen of your Bluetooth device e g OPEN and clicking or physically touching the Pad on the RIFT 400 Please note that some parameter ch...

Page 20: ...RTIONAL CONTROL FUNCTION Electronic Positioning System EPS The RIFT 400 can be Bluetooth configured to select modulating control see page 9 for using Bluetooth with the RIFT 400 For modulating control...

Page 21: ...rs only and will not control the movement of the Valve Actuator when Analogue Signal Control is selected this is primarily used as a charging circuit Unnecessary frequent movement instigated by a cons...

Page 22: ...ftware Updates and or New Features DEFINITIONS ABBREVIATION Definitions Abbre viation Explanation AC Alternating Current DC Direct Current PCD Pitch Circle Diameter LCM Local Control Mode PID Proporti...

Page 23: ...sion 1 2 23 DOCUMENT REVISION TABLEDOCUMENT REVISION TABLE Date Name Revision Details 25 10 2019 Brown 1st revision for RIFT 400 Sub Sea and Android App 06 05 2020 Fabio Musio Change all SmartAct to R...

Reviews: