55
ATTO Technology Inc. FibreBridge Installation and Operation Manual
2.5.6 Fibre Channel configuration commands
The Fibre Channel ports are configured with default settings but may be customized using CLI. Any
commands which require Ethernet are not available for ATTO FibreBridge 1180 models. Refer to the
CLI summary reference
on page 41 to determine which CLI commands apply to your model.
BootFibreDelay
Initialization of the FC port is delayed by 0, 15 or 30
seconds to allow a connected Fibre switch to fully
initialize before enabling the FibreBridge FC ports.
Default: 0 (no delay)
Set syntax: set BootFibreDelay [0 | 15 | 30 ]
Requires a SaveConfiguration command
Get syntax: get BootFibreDelay
BootScan
Provides dynamic mapping of SCSI devices to the Fibre
port/LUN combination via a SCSI bus scan at boot time.
All devices discovered during the bus scans will be
assigned to a Fibre port, Fibre LUN combination until the
next reset/power cycle. This dynamic mapping will
replace the current, static mapping of the FibreBridge.
Default: disabled
Set syntax: set BootScan [enabled | disabled]
Requires a SaveConfiguration command
Get syntax: get BootScan
BootScanPorts
For legacy applications, selects/displays the ports to be
used for a boot scan.
Default: auto
Set syntax: set BootScanPorts [fp | all | auto]
Requires a SaveConfiguration command
Get syntax: get BootScanPorts
DispFcPortDB
Used to display the contents of the specified FC port’s
internal port database if the command
FCInitiator
is
enabled. The database contains FC addressing
information for each FC target device visible to the
FibreBridge.
Information only: DispFcPortDB <fp>
FcAck0
Specifies whether ACK0 or ACK1 will be returned in
response to a Class 2 FC data frame or sequence. Enable
sends ACK0 at the end of a sequence. Disable returns an
ACK1 frame for each data frame.
Default: disabled
Set syntax: set FcAck0 [enabled | disabled]
Requires a SaveConfiguration command
Get syntax: get FcAck0
FcClass2
Specifies if the FibreBridge will support FC Class 2
(multiplexed) service. The FibreBridge uses Class 3
service by default.
Default: disabled
Set syntax: set FcClass2 [enabled | disabled]
Requires a SaveConfiguration command
Get syntax: get FcClass2
FcConnMode
Controls/reports the connection mode the FibreBridge
uses when communication across a FC network, either to
an arbitrated loop (FC-AL) when you select
loop
mode,
or point-to-point when you choose
ptp.
Default: loop
Set syntax: set FcConnMode [loop | ptp]
Requires a SaveConfiguration command
Get syntax: get FcConnMode
FcDataRate
Specifies the rate the FibreBridge will use, 1 Gigabit/sec.,
2 Gigabit/sec. 4 Gigabit/sec. or auto negotiate.
Default: auto
Set syntax: set FcDataRate [1Gb | 2Gb | 4Gb | auto]
Requires a SaveConfiguration command
Get syntax: get FcDataRate
Summary of Contents for ATTO FibreBridge 2350C
Page 2: ......
Page 3: ......
Page 11: ......
Page 29: ...18 Installation FibreBridge 2300R D Exhibit 1 5 3 FibreBridge 2300 board layout...
Page 79: ...68 Configuration mapping Exhibit 3 1 1 Mapping using ATTO ExpressNAV...
Page 85: ...74 Configuration mapping...
Page 105: ...xiv Appendix...
Page 109: ...xviii...