- 7 -
Information of Gas Supply and Electric:
The internal thread of product
’
s intake-tube is
3/4" NPT.
DO NOT EXCEED GAS PRESSURES GREATER THAN THE FOLLOWING:
(
Table 1
)
GAS PRESSURE
NATURAL GAS
PROPANE GAS
AT INLET
13.84 in.W.C./3.45kPa 13.84 in.W.C./3.45kPa
AT MANIFOLD
3.5 in.W.C./0.87kPa
10 in.W.C./2.49kPa
PER BURNER
23,000 BTU/HR
23,000 BTU/HR
PER OVEN
46,000 BTU/HR
46,000 BTU/HR
INJECTOR
43#(
φ
2.26mm)
54#(
φ
1.40mm)
VOLTS
115
AMPS
9.0
PH.
1
HZ.
60
5. Transport and Storage
In the process of transportation, handle carefully and keep upright to
prevent damage of the product packing. Wrapped equipment should not be
in open air for a long time, and shall be placed in a well-ventilated and
non-corrosive gases warehouse. When equipment needs temporary storage,
rainproof measures should be taken.
6. Installation and Debugging
Any erroneous installation, adjustment, refit, overhaul or
maintenance may
cause property damage or personal injury. The work
shall be performed by authorized and licensed technicians, otherwise
the manufacturer has the right not to provide warranty service;
Only be installed in accordance with the local code. If no similar
standard, you should conform to the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, the National Gas Installation Code, CSA-B149.1, or the