- 14 -
the panel out, and the pressure test
point is on the right.
●
Remove needle type pressure joint screw
arbor (Fig.1), then slip rubber tube of
pressure gauge over needle type pressure
joint;
●
Start the equipment in accordance with the
instructions, measuring gas supply pressure
(dynamic pressure) in the work state;
●
Access to the equipment if measured data Figure 1
within the limits of Table 1, otherwise,
you will need to adjust gas pressure
regulating valve or contact gas supplier
to bargain;
●
Unplug pressure gauge after you accomplish pressure testing, then
install needle type pressure joint screw arbor.
Important: must screw joint screw arbor, to prevent gas escape!
It
’
s very important to debug the new stove. Through the
comprehensive system test of equipment, we can ensure function and
safety performance of products. Discovering any potential problems
before use (such as equipment
’
s placement, ventilation, operation, etc),
can avoid costly losses.
7. Safety Notices and Precautions
Warning! For your safety, do not place petrol and other flammables
nearby. Please keep clean and free of flammables surroundings. (Read
ANSI Z83.14B, 1991 for reference)
Warning! Any erroneous installation, adjustment and refit may
cause property damage or personal injury and maintenance failure.
Read the instructions carefully before installation and using.
Warning! Operation instruction must be placed in a conspicuous
location. When customers smell gas in the process of using, should take
Needle type
pressure joint screw
arbor