- 12 -
The area around the oven must be kept clear of combustible materials. A
minimum clearance must be maintained between the oven and any
combustible or non-combustible surface;
MINIMUM CLEARANCES
Combustible
Non-Combustible
RIGHT SIDE
1"
1"
LEFT SIDE
1"
1"
REAR
6
6
FLOOR
6"
6"
Do not put anything around the equipment, and on the counter top and
bottom, in order to avoid influencing combustion and air circulation;
This oven has been tested and certified for use on gas systems that do
not exceed 1/2 psi (3.45kPa) or pressure. If the piping system is tested at a
pressure higher than 1/2 psi (3.45kPa),this oven should be isolated from the
supply by disconnecting it. If the piping system is tested at a pressure lower
than or equal to 1/2 psi (3.45kPa),this oven should be isolated from the
supply by shutting off the manual shut off valve located on the front panel.
ELECTRICAL CONNECTIONS
Your oven is supplied for connection to a 115 volt, single phase
grounded circuit. The electric motor, oven lights, indicator lights and control
circuits are connected through a seven-foot electric supply cord found at
the rear of the oven.
Before making any connections to these units, check the rating plate to
assure that the voltage and phase of the oven is compatible with the electrical
supply. When installing, all ovens must be electrically grounded in accordance
with local codes, or in the absence of local codes, with the National Electrical
Summary of Contents for ATCO-513B-1
Page 7: ... 5 4 2 ATCO 513B Double Stacked Ovens ...
Page 8: ... 6 ...
Page 13: ... 11 ...
Page 31: ... 29 10 ELECTRICAL SCHEMATIC ...
Page 32: ... 30 ...
Page 33: ... 31 ...