- 13 -
Code, ANSI/NFPA70 (in Canada-CSA Std.C22.2).Wiring diagrams are located in
the control compartment area of the oven. Standard wiring schematics are also
provided with this manual.
WARNING
:
This appliance is equipped with a three-prong (grounding)
plug for your protection against shock hazard and should be plugged directly
into a properly grounder three-prong receptacle. DO NOT cut or otherwise
remove the grounding prong from this plug
.
VENTILATION
Proper ventilation is very important for the proper function of your oven. A
good ventilation system will allow the oven to function properly as well as
remove unwanted vapors and products of combustion. Not venting the ovens
properly can result in unsatisfactory baking results as well as the possibility of
damaging your oven. To keep your warranty in force, a proper ventilation
system must be employed, either direct vented or under a canopy;
Warning! Use soap water or testing instrument to test whether
piping joint leaks or not before using, and forbid using an open flame to
test!
After installing completely, you should check gas supply pressure. Use
a pressure gauge which is equipped with liquid (such as U-type
pressure gauge, the minimum value is 0.1mbar) or a digital pressure
gauge to test. Steps are as following:
●
After opening the door, loosen the four
screws that hold the lower panel, pull