![ATON RA.Store-3 Installation Manual Download Page 50](http://html1.mh-extra.com/html/aton/ra-store-3/ra-store-3_installation-manual_3004692050.webp)
50
Picture 77 – Calc. Ah Battery
- Rigen.Enable/Disable (4): from this menu it is possible to give the following instructions (Picture 78):
•
Rigen.90% Enable: this command enables the function “recharge battery up to 90% of the Soc”; if in the
last 15 days of the solar month the battery did not execute a charge up to 90% of the Soc, the first day of
the month the storage system uses first the energy of the PV panels to charge the battery up to 90% of
the Soc, rather than giving it to the house.
•
Rigen.90% Disable: this command disables the function “recharge battery up to 90% of the Soc”.
•
Rigen.90% Start: this command enables the function “recharge battery up to 90% of the Soc”.
•
Rigen.90% Stop: this command stops the function “recharge battery up to 90% of the Soc”.
Picture 78 - Rigen. Enable/Disable
- Soc Ah/Volt/BMS (5): from this menu you can choose how the card visualizes the Soc value (Picture 79):
•
Soc Ah: according to the charged Ah in 24 hours, it is calculated a value of Soc according to the capacity of
rated storage of the battery.
•
Soc Volt: according to the tension of the battery, it is calculated a value of Soc.
•
Soc BMS: the Soc value is visualized according to the value of Soc read by the Battery Management
System.
Picture 79 - Soc Ah/Volt/BMS: choice