![ATON RA.Store-3 Installation Manual Download Page 48](http://html1.mh-extra.com/html/aton/ra-store-3/ra-store-3_installation-manual_3004692048.webp)
48
- External Inverter (6): from this menu it is possible to configure an energy measuring unit like a meter, installed
on the exit of the AC side of an inverter available on the installation but not connected to the storage system. It is
necessary that together with the meter it is also available the converter RS232/RS485 Aton (article KIT232-485-
DIN) in order to realize the communication with the manager card of the storage system (Picture 73).
The possible choices are the following:
•
0: disabled function
•
1: single phase meter brand Carlo Gavazzi model EM100
•
2: three-phase meter connected to a single phase inverter brand Carlo Gavazzi, model EM24 (article
EM24DINAV93XISX).
•
3: three-phase meter connected to a three-phase inverter brand Carlo Gavazzi, model EM24 (article
EM24DINAV93XISX).
Picture 73 - External Inverter: choice of the meter Carlo Gavazzi
Meter for the reading of the
external set up inverter