AT-UHD-SW-510W
39
Auto Power Off Timer
Click this drop-down list to set the time interval, in seconds, between when the loss of A/V signal is detected and
when the “Display Off” command is sent to the display. Range: 0 to 300. The default value is 1 minute.
The Web GUI
Control Type
Click this drop-down list to select the control method for sending commands to the sink device. The default setting is
CEC. Refer to ## for more information on control types and their settings.
Setting
Description
RS-232
RS-232 is used to send commands.
IP
Commands are sent over IP.
CEC
Uses CEC to send commands.
Control Types
The
Control Type
drop-down list selects the method for sending commands to the display device.
• RS-232
When
RS-232
is selected, both the
HDBaseT RS-232
and
RS-232/IP Commands
section will be displayed.
1. Under the
HDBaseT RS-232
section, set the baud rate, data bits, parity bit, and stop bit for RS-232.
Setting
Description
Baud rate
Sets the baud rate. The following options are available: 9600, 14400, 19200,
38400, 57600, 115200. The default baud rate is 9600.
Data bit
Sets the number of data bits used to represent each character of data. The
following options are available: 7 or 8. The default setting is 8.
Parity
Sets the parity bit, which can be included with each character to detect
errors during the transmission of data. The following options are available:
None, Odd, or Even. The default setting is none.
Stop bit
Sets the stop bit. Stop bits are sent at the end of each character, allowing
the client to detect the end of a character stream. The following options are
available: 1 or 2. The default setting is 1.