ASUS ESC8000 G3
6-19
3.
When prompted, use the arrow keys to select Yes from the Consistency Check? dialog
box, and then press <Enter>.
A progress bar appears on screen.
4.
While checking the disk consistency, press <Esc> to display the following options.
•
Stop
Stops the consistency check. The utility stores the percentage of
disk checked, and when you restart checking, it continues from the last
percentage completed rather than from zero percent.
•
Continue
Continues the consistency check.
•
Abort
Aborts the consistency check. When you restart checking, it continues
from zero percent.
5.
When checking is complete, press any key to continue.
SPACE-(De)Select, F10-Initialize
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Select VD(s)
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 10 154494MB 2 64KB ONLINE
Virtual Drive 0
Virtual Drives
Yes
No
Consistency Check?
SPACE-(De)Select, F10-Initialize
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
The Data On The Drives Is Inconsistency. Repair Done!
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 10 154494MB 2 64KB ONLINE
Virtual Drive 0
Virtual Drives
CC Under Process
VD 0 Consistency Check. Press Esc to Abort.
85% Completed
Summary of Contents for ESC8000 G3
Page 1: ...3U Rackmount Server ESC8000 G3 User Guide ...
Page 35: ...2 13 ASUS ESC8000 G3 19 Replace the CPU air duct 20 Tighten the screws on the CPU air duct ...
Page 62: ...4 2 Chapter 4 Motherboard Information 4 1 Z10PG D24 Motherboard layout ...
Page 84: ...4 24 Chapter 4 Motherboard Information ...
Page 136: ...5 52 Chapter 5 BIOS Setup ...
Page 176: ...6 40 Chapter 6 RAID Configuration ...