25
Installation Instructions
SE LP10 9600 Series Exit Device
With MELR
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
a. Insert key into cylinder and rotate.
b. With key rotated turn lever and check that latch retracts.
c. Check that push bar fully retracts the latch.
d. Close door: Ensure latch fully extends into strike and
does not bind.
Note: For fail safe trim cylinder will have to be tested after wiring
is complete and power is turned on.
10) Operational Check
9) Door Postion Switch Installation
a.
Install Door Position Switch supplied with product:
• Drill 1” hole in door for magnet
• Drill 1” hole in frame for switch
b.
Wire to ElectroLynx
®
frame harness as shown in
wiring diagram on previous page.
Door Position
Switch