background image

4

Installation Instructions

SE LP10 9600 Series Exit Device 

With MELR

Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All 

rights reserved. Reproduction in whole or in part without the express written 

permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.

The Corbin Russwin SE LP10 Series exit device is designed to interface with existing Wired Electronic  
Access Control (EAC) panels. The reader requires 12VDC for power and features HID

®

 multiCLASS SE

®

  

technology. The technology is designed around Corbin Russwin’s Grade 1 hardware. The exit device  
comes with touch bar monitoring (REX) and is provided with an external Door Position Switch (DPS).  
Featuring EcoFlex™ technology, the lock operates from 12-24VDC.

• 

Door Thickness – 1-3/4” Standard; Can be furnished for    

    

   other door thicknesses upon request. Consult factory.
•  Outside lever controlled by reader or key allows lever to  

    

    retract latch
•  Inside push bar produces REX (request to exit) signal and  

     

    retracts latch
•  Fail Safe or Fail Secure Operation (must specify)
•  UL fire listed available
•  Wires directly to EAC panels
•  Wire from EAC Panel to door must be shielded with a    

     

    drain. Drain terminated at EAC Panel controller.
•  Supports multiple credential formats:

3) General Description

4) Specifications / Features

The reader requires 12VDC for power,   

   

 while the lock accepts 24VDC.

DPS (Door 

Position Switch)

McKinney
Electronic 

Transfer

Hinge

Wiegand Access 

Control System

ED5000N Exit Device

9600 Series Trim

     • 

125 kHz credential compatibilty

:

 

  

• HID Prox

®

, AWID, EM4102

• 

13.56 MHz credential compatibility:

• Secure Identity Object

 (SIO) on iCLASS Seos, iCLASS SE/SR, 

   MIFARE DESFire EV1/EV2 and MIFARE Classic (on by default)
• Standard iCLASS Access Control Application, ISO14443A (MIFARE) 

  CSN, ISO14443B CSN, and ISO15693 CSN
• ISO14443A/B (PIV-compatible Transparent FASC-N read) available with  
   SE LP10-F

 (

**

not available with Alternate Indicator Configuration

**

)

• NFC-enabled mobile phones

• 2.4 GHz credential compatibility 

• Secure Identity Object

 (SIO) on Mobile IDs (Bluetooth Smart)

For Mobile Credential-Enabled versions of this electronic lock

 

(Indicated by “BIPS” in the product order string):
  • Mobile Credentials are transmitted to the lock via Bluetooth Smart or NFC ISO/IEC14443 and 

     must use a mobile device enabled with these technologies.
  • Credential and mobile device versions are specified by the credential provider.
  • User must acquire the latest HID “Mobile Access” application available from Apple iStore or 

     Android PlayStore.

Electrical Specifications

 

• Reader Draw = 150mA @12 / 24VDC

 

• Actuator Draw = 400mA inrush / 15mA continuous @12 / 24VDC

 

• Total System Draw = 550mA @12/24VDC

Summary of Contents for Corbin Russwin SE LP10 9600 Series

Page 1: ...nment can cause premature wear and a lessening of security For Technical Assistance call Corbin Russwin at 1 800 810 WIRE 9473 Attention Installer Installation Instructions SE LP10 9600 Series Exit De...

Page 2: ...ut the express written permission of ASSA ABLOY Access and Egress Hardware Group Inc is prohibited Table of Contents 1 Regulatory Compliance 3 2 Warning 3 3 General Description 4 4 Specifications Feat...

Page 3: ...her antenna or transmitter Cet quipement est conforme aux limites d exposition aux radiations de la FCC d finies pour un environnement non contr l Cet quipement doit tre install et utilis une distance...

Page 4: ...multiple credential formats 3 General Description 4 Specifications Features The reader requires 12VDC for power while the lock accepts 24VDC DPS Door Position Switch McKinney Electronic Transfer Hing...

Page 5: ...IPS B03 Reader Harness Assembly 200 bit Wiegand output 763F669 FIPS B04 Reader Harness Assembly 75 bit Wiegand output 763F629 IPS B03 Reader Harness Assembly Standard Indicator Configuration 784F869 I...

Page 6: ...Standard Indicator Configuration 1 763F649 FIPS B03 Reader Harness Assembly 200 bit Wiegand output 763F669 FIPS B04 Reader Harness Assembly 75 bit Wiegand output 763F629 IPS B03 Reader Harness Assemb...

Page 7: ...g a FIPS 201 PIV credential causes LED to turn amber as credential is authenticated Reader emits a short beep when credential is successfully read Reference Diagram 1 PIN 4 Tan DPS COM PIN 2 Gray Lock...

Page 8: ...NO Fail Secure Operation DPS DPS QC12 Electric Hinge From McKinney Panel Circuitry Unsupervised Open Collector Tamper 5VDC A to D Converter 1K 1K 1K Input Connection Input Connection IMPORTANT Pin 7...

Page 9: ...wn 7 GREEN_LED Yellow 8 LOCK NEG Violet 9 LOCK POS Gray 10 DPS NC Pink 11 DPS COM Tan 12 12VDC DATA 1 DATA 0 RX NO RX COM Electrical Access Control Panel By Others Use NC for Fail Safe Operation Lock...

Page 10: ...eak Average Peak Reader 100mA 220mA n a n a MELR n a n a 250mA dogged 1A inrush 600mA during retraction UL294 S319 BHMA A156 25 currently not applicable to TAMPER or Alternate Indicator option 8F 4F 8...

Page 11: ...Reader 8F 4F Not used 3287 Door Position Switch DPS RX COM Blue 6 EARTH GROUND Brown 7 GREEN_LED Yellow 8 DATA 1 DATA 0 RX NO RX COM Electrical Access Control Panel By Others Use NC for Fail Safe Ope...

Page 12: ...for size of exit device function and hand 2 Prep door according to supplied door markers Outside FM382 for Rim SVR CVR FM386 for Mortise Inside FM387 Left Hand Reverse LHR Outside Inside Right Hand Re...

Page 13: ...plate and gasket using two 2 8 18 x 5 8 Phillips flat head self drilling screws Fig 3b 3 For non fire rated interior doors no fire shield or gasket is required simply install backplate using two 2 8 1...

Page 14: ...und the reader Ensure access hole in the bezel aligns with screw hole on reader The reader should be mounted so holes face bottom of door Fig 4b 2 Align top of reader with top of backplate Pivot the r...

Page 15: ...Fig 5a for Mortise skip to Step 6 b If required modify by cutting cylinder tailpiece Correct length is 1 16 to 3 16 2 to 5mm beyond cylinder housing cam c Assemble cylinder 1 Insert cylinder housing p...

Page 16: ...s Hardware Group Inc is prohibited 7 Installation Instructions Continued Install mortise lock following FM168 instructions but do not install armored front at this time a Feed lock wire through wire h...

Page 17: ...reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group Inc is prohibited Fig 6c d Tighten down set screw to prevent cylinder m...

Page 18: ...Trim Assembly Rim CVR SVR a Make sure tailpiece is oriented vertically b Feed trim wire harness through wire harness hole Fig 7 c Mount trim assembly to door pulling slack wire towards device side of...

Page 19: ...hibited 7 Installation Instructions Continued 8 Install Exit Device Follow instructions packed with device to secure device to door 9 Install Head Cover a Lay wire device harnesses across hole Fig 9a...

Page 20: ...Fig 10a a Feed reader harness through mounting plate Fig 10a b b For Rim CVR and Mortise Begin to secure mounting plate to inside door surface by fastening 2 Phillips flat head machine screws to lower...

Page 21: ...pin connector on reader harness Fig 11a b 11 Connector Attachments Fig 11b Fig 11c Fig 11a c Connect ElectroLynx 4 and 8 pin connectors from the door harness to black 4 and 8 pin connectors of the re...

Page 22: ...ws no fire plate required 7 Installation Instructions Continued a NOTE For fire rated doors only Secure mounting plate and fire plate using 2 8 1 1 4 Phillips pan head self drilling screws provided Fi...

Page 23: ...a Feed excess ElectroLynx wire harness back into door b Feed excess trim and exit device harnesses under head cover c Install inside escutcheon using 2 8 32 x 5 8 oval head screws Fig 13a Note Be care...

Page 24: ...ration and Operational Check Not Used Do not install the end cap until electrical operation is verified in order to confirm LED signaling Do not discard the end cap and hardware Configuration Check a...

Page 25: ...tated turn lever and check that latch retracts c Check that push bar fully retracts the latch d Close door Ensure latch fully extends into strike and does not bind Note For fail safe trim cylinder wil...

Page 26: ...he test unit checks for proper wiring card reader data integrity lock functionality including lock unlock door position status and request to exit REX status In addition this tool provides product dem...

Page 27: ...ies Exit Device With MELR Copyright 2020 ASSA ABLOY Access and Egress Hardware Group Inc All rights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Acces...

Page 28: ...and Edge are trademarks or registered trademarks of HID Global in the U S and or other countries All other trademarks service marks and product or service names are trademarks or registered trademarks...

Reviews: