Installation Instructions
SE LP10 9600 Series Exit Device
With MELR
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Alternate Indicator Configuration Application Diagram #4
Connect GREEN_LED input to switch controlled by panel. Shorting GREEN_LED to READER_NEG (Black) with
panel switch will override reader LED to keep it green.
Reader Electronics Requires 12VDC Filtered and Regulated
12V
24V
Average
Peak
Average
Peak
Reader
100mA
220mA
n/a
n/a
MELR
15mA
500mA
15mA
500mA
-
**UL294, S319, & BHMA A156.25 currently not applicable to TAMPER or Alternate Indicator option
MELR requires 24VDC
8F
4F
8M
4F
8F
4F
4M
8M
8M
4M
4M
4M
8M
8M
SELP10
Reader
8F
4F
Not used
3287 Door
Position Switch (DPS)
RX (COM) - Blue, 6
*EARTH GROUND - Brown, 7
**GREEN_LED - Yellow, 8
DATA 1
DATA 0
RX (NO)
RX (COM)
Electrical
Access
Control
Panel
(By Others)
Use (NC) for
Fail Safe
Operation
Lock
Relay
(NO) Fail
Secure
Operation
DPS
DPS
Panel Circuitry
Power Supply
(By Others)
12-24VDC
H N G
120 VAC
Input
Black (Hot)
White (Neutral)
Gr
een (Gnd)
12VDC
- +
- +
8F
4F
8M
4M
†NOTE: All Door Cables, Frame
Cable and QC12 Hinge are
specified & ordered seperately
Wiring shown is inside door frame
MELR Exit Device
Not
used
Not
used
Not
used
8-pin to 4-pin
3 “ Adaptor
Harness
Required
Supplied
Not
used
†Male to Male
Adaptor Door Cable
12 Conductor
(3” length typically)
†Door Cable - 12 conductor
(length selected by door width)
†QC12
Hinge
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO) - Orange, 5
MELR NEG - Violet, 1
MELR POS - Gray, 2
Not Used- Pink, 3
*EGND - Tan, 4
*IMPORTANT: Pin 7 - Brown and 4 - Tan must be tied to earth ground in the access control panel.
+
12VDC
(NO)
Panel Relay
(NC)
6) Wiring Diagrams (Continued)