![ASI Tiger TG-1000 Instruction Manual Download Page 73](http://html1.mh-extra.com/html/asi/tiger-tg-1000/tiger-tg-1000_instruction-manual_2982756073.webp)
11
The reporting precision of the
WHERE
command can be changed with the
VB Z
command.
Command: WHO
(TG-1000 v1.6+)
Shortcut
N
Format:
WHO
Function:
In TG-1000 it prints all the card address, axis characters, build name and compile date,
of all cards installed in the system. It’s a
Comm-default Command.
Example:
N
At 30: Comm v1.6 TIGER_COMM Jul 02 2013:17:19:34
At 31: X:XYMotor,Y:XYMotor v2.4 STD_XY Jun 11
2013:10:24:35
At 32: P:MMirror,Q:MMirror,R:MMirror,S:MMirror v2.4
MMIRROR_4CH May 10 2013:16:22:55
Command: WRDAC
(not supported on TG-1000)
Format:
[addr#]WRDAC [axis]=###
Function:
Lets the user set the voltage on header pin SV1-5 on WK2000 board. The voltage can be
varied between 0 and 10 Volts, with an accuracy of 0.1V. Maximum Output drive
current is 35mA. Input value in volts. Does not work with Piezo units.
Reply:
If there are no errors, a positive response of
:A
will be returned.
Example
1WRDAC X=1.1
:A
(Voltage on PIN SV1-5 is 1.1Volts)
WRDAC X=20 OR -1
:N-4
(Parameter out of range)
Command: ZERO
Shortcut:
Z
Format:
ZERO
Function:
Writes a zero to the position buffer of all axes. Allows the user to set current position as
the origin. It’s a
Broadcast Command.
Summary of Contents for Tiger TG-1000