Command: RELOCK
(For CRIFF and AF-DUAL Systems)
Shortcut:
RL
Format:
[Addr#]RL
Function:
Turns on the CRIFF laser and initiates a
LOCK
state using previously saved reference
values. Same as LOCK for AF-DUAL systems. It’s a
Card-Addressed command.
Reply:
:A
is returned upon receipt of the command.
Command: RESET
Shortcut:
~
Format:
RESET
Function:
This command causes the controller to do a software reset. A software reset
reinitializes all variables back to their pre-assigned values. It’s usually a
Broadcast
command
but can be used as a
Non-Addressed Command
as well. When addressed to a
specific card, it resets that card and then the Comm card (required to communicate with
the reset card) without affecting other installed cards.
Example:
RESET
:R
Command: RTIME
Shortcut:
RT
Format:
[Addr#]RT [X=report_time] [Y=pulse_length in ms]
[Z=delay_time in ms] [F=num_aves]
Function:
The X argument sets the time interval between report events when using